ArticleJournal of medical imaging (Bellingham, Wash.)2023
Implications for downstream workload based on calibrating an artificial intelligence detection algorithm by standalone-reader or combined-reader sensitivity matching.
Article in Journal of medical imaging (Bellingham, Wash.), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Performance of artificial intelligence in breast cancer screening programmes: a systematic review.BMJ open · 2025Pooled it
- Retrospective evaluation of a CE-marked AI system, including 1,017,208 mammography screening examinations.European radiology · 2025Article
- Risk inventory and mitigation actions for AI in medical imaging-a qualitative study of implementing standalone AI for screening mammography.BMC health services research · 2025Article
- Artificial Intelligence Algorithm for Subclinical Breast Cancer Detection.JAMA network open · 2024Article
- AI performance by mammographic density in a retrospective cohort study of 99,489 participants in BreastScreen Norway.European radiology · 2024Article
- Performance of an Artificial Intelligence System for Breast Cancer Detection on Screening Mammograms from BreastScreen Norway.Radiology. Artificial intelligence · 2024Article
- Artificial Intelligence in Breast Cancer Diagnosis and Personalized Medicine.Journal of breast cancer · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: In double-reading of screening mammograms, artificial intelligence (AI) algorithms hold promise as a potential replacement for one of the two readers. The choice of operating point, or abnormality threshold, for the AI algorithm will affect cancer detection and workload. In our retrospective study, the baseline approach was based on matching stand-alone reader sensitivity, while the alternative approach was based on matching the combined-reader sensitivity of two humans and of AI plus human. Approach: Full-field digital screening mammograms within the Stockholm County area between February 1, 2012, and December 30, 2015, acquired on Philips equipment, were collected. All exams of women with breast cancer within 23 months of screening and a random selection of healthy controls were included. An exam-level continuous AI abnormality score was generated (Insight MMG from Lunit Inc). Sensitivity and abnormal interpretation rates were estimated for operating points defined by the standalone-reader approach and the combined-reader approach. Results: The study population included 1684 exams of women with breast cancer and 5024 exams of healthy women. Observations of healthy women were up-sampled to attain a realistic proportion of cancer. The observed sensitivity for reader 1, 2 and 1+2 was 69.7%, 75.6%, and 78.6%, respectively, at an abnormal interpretation rate of 4.4%, 4.6%, and 6.1%, respectively. For the combination of reader 1 + AI we estimated a sensitivity of 82.4% for standalone-reader matching and 78.6% for combined-reader matching, at an abnormal interpretation rate of 12.6% and 7.0%, respectively. Conclusions: Setting the operating point by matching stand-alone AI stand-alone with a radiologist will nearly double the downstream workload compared to a modest increase of 15% for the alternative method of matching sensitivity between the combination of AI and a radiologist with two radiologists.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.