Evidence map›Paper›PMID 37034965›Full record

ArticleSensors & diagnostics2022

Single-channel digital LAMP multiplexing using amplification curve analysis.

Kenny Malpartida-Cardenas, Luca Miglietta, Tianyi Peng, Ahmad Moniri, Alison Holmes, Pantelis Georgiou, Jesus Rodriguez-Manzano

Open access · diamondAbstract read
In one paragraph

Article in Sensors & diagnostics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.1field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 14 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Kenny Malpartida-Cardenas *Department of Infectious Disease, Imperial College London, London W12 0NN, UK.ORCID https://orcid.org/0000-0002-3874-8810
Luca Miglietta *Department of Infectious Disease, Imperial College London, London W12 0NN, UK.ORCID https://orcid.org/0000-0002-6652-4785
Tianyi PengDepartment of Infectious Disease, Imperial College London, London W12 0NN, UK.
Ahmad MoniriDepartment of Electrical and Electronic Engineering, Imperial College London, London SW7 2AZ, UK.
Alison HolmesDepartment of Infectious Disease, Imperial College London, London W12 0NN, UK.
Pantelis GeorgiouDepartment of Electrical and Electronic Engineering, Imperial College London, London SW7 2AZ, UK.
Jesus Rodriguez-ManzanoDepartment of Infectious Disease, Imperial College London, London W12 0NN, UK.ORCID https://orcid.org/0000-0002-2583-8366
Imperial College London · GB

Funding

Department of Health IS-HPU-1112-10047
6 · The paper itself

Abstract

Loop-mediated isothermal amplification assays are currently limited to one target per reaction in the absence of melting curve analysis, molecular probes or restriction enzyme digestion. Here, we demonstrate multiplexing of five targets in a single fluorescent channel using digital LAMP and the machine learning-based method amplification curve analysis, resulting in a classification accuracy of 91.33% on 54 186 positive amplification events.

Identifiers

PMID37034965
PMCPMC7614402
OpenAlexW4225957968

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.