ArticleFrontiers in cardiovascular medicine2023
Machine learning-based analysis of risk factors for atrial fibrillation recurrence after Cox-Maze IV procedure in patients with atrial fibrillation and chronic valvular disease: A retrospective cohort study with a control group.
Article in Frontiers in cardiovascular medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 1 synthesis or guideline pooled it, 4 citations in OpenAlex.
- Predictive value of neutrophil to lymphocyte ratio for clinical outcome in patients with atrial fibrillation: a systematic review and meta-analysis.Frontiers in cardiovascular medicine · 2024Pooled it
- Machine learning and deep learning predictive models for prognosis in patients with atrial fibrillation: a systematic review and meta-analysis.BMJ digital health & AI · 2025Article
- Comparison of short-term efficacy of two bipolar radiofrequency ablation forceps for rheumatic heart disease concomitant with atrial fibrillation.Frontiers in cardiovascular medicine · 2024Article
- Novel Entropy-Based Metrics for Long-Term Atrial Fibrillation Recurrence Prediction Following Surgical Ablation: Insights from Preoperative Electrocardiographic Analysis.Entropy (Basel, Switzerland) · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Objectives: To evaluate the efficacy of the Cox-Maze IV procedure (CMP-IV) in combination with valve surgery in patients with both atrial fibrillation (AF) and valvular disease and use machine learning algorithms to identify potential risk factors of AF recurrence. Methods: A total of 1,026 patients with AF and valvular disease from two hospitals were included in the study. 555 patients received the CMP-IV procedure in addition to valve surgery and left atrial appendage ligation (CMP-IV group), while 471 patients only received valve surgery and left atrial appendage ligation (Non-CMP-IV group). Kaplan-Meier analysis was used to calculate the sinus rhythm maintenance rate. 58 variables were selected as variables for each group and 10 machine learning models were developed respectively. The performance of the models was evaluated using five-fold cross-validation and metrics including F1 score, accuracy, precision, and recall. The four best-performing models for each group were selected for further analysis, including feature importance evaluation and SHAP analysis. Results: The 5-year sinus rhythm maintenance rate in the CMP-IV group was 82.13% (95% CI: 78.51%, 85.93%), while in the Non-CMP-IV group, it was 13.40% (95% CI: 10.44%, 17.20%). The eXtreme Gradient Boosting (XGBoost), LightGBM, Category Boosting (CatBoost) and Random Fores (RF) models performed the best in the CMP-IV group, with area under the curve (AUC) values of 0.768 (95% CI: 0.742, 0.786), 0.766 (95% CI: 0.744, 0.792), 0.762 (95% CI: 0.723, 0.801), and 0.732 (95% CI: 0.701, 0.763), respectively. In the Non-CMP-IV group, the LightGBM, XGBoost, CatBoost and RF models performed the best, with AUC values of 0.738 (95% CI: 0.699, 0.777), 0.732 (95% CI: 0.694, 0.770), 0.724 (95% CI: 0.668, 0.789), and 0.716 (95% CI: 0.656, 0.774), respectively. Analysis of feature importance and SHAP revealed that duration of AF, preoperative left ventricular ejection fraction, postoperative heart rhythm, preoperative neutrophil-lymphocyte ratio, preoperative left atrial diameter and heart rate were significant factors in AF recurrence. Conclusion: CMP-IV is effective in treating AF and multiple machine learning models were successfully developed, and several risk factors were identified for AF recurrence, which may aid clinical decision-making and optimize the individual surgical management of AF.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.