ArticleMicrosystems & nanoengineering2023
3D-printing-assisted flexible pressure sensor with a concentric circle pattern and high sensitivity for health monitoring.
Article in Microsystems & nanoengineering, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed.
- An integrated polyacrylonitrile fiber mat sensor for simultaneous temperature and pressure monitoring in high-temperature environments.Microsystems & nanoengineering · 2026Article
- Wearable Sensors Fabricated by 3D-Printed Composite Hydrogel with 2D Fillers.Small methods · 2026Review
- Self-Assembled MXene/MWCNTs Pressure Sensors Combined with Novel Hollow Microstructures for High Sensitivity.Micromachines · 2025Article
- The 3D Printing of Flexible Materials: Technologies, Materials, and Challenges.Materials (Basel, Switzerland) · 2025Review
- Wearable Flexible Wireless Pressure Sensor Based on Poly(vinyl alcohol)/Carbon Nanotube/MXene Composite for Health Monitoring.Micromachines · 2025Article
- A switchable dynamic-static tactile system for augmented haptic secret communication.Science advances · 2025Article
- Influence of Substrate Material and Sensor Geometry Variations on the Performance of Fused Deposition Modeling-Printed Strain Sensors.3D printing and additive manufacturing · 2025Article
- Pressure Induced Molecular-Arrangement and Charge-Density Perturbance in Doped Polymer for Intelligent Motion and Vocal Recognitions.Advanced materials (Deerfield Beach, Fla.) · 2025Article
- Bridging Additive Manufacturing and Electronics Printing in the Age of AI.Nanomaterials (Basel, Switzerland) · 2025Review
- Detection of Positive and Negative Pressure in a Double-Chamber Underwater Thruster.Micromachines · 2025Article
- Wide-Range, Washable Piezoresistive Pressure Sensor Based on MCNT-PDMS Dip-Coated PDMS Sponge.Micromachines · 2025Article
- Flexible Pressure Sensor with Tunable Sensitivity and a Wide Sensing Range, Featuring a Bilayer Porous Structure.Micromachines · 2025Article
- Smart Driving Hardware Augmentation by Flexible Piezoresistive Sensor Matrices with Grafted-on Anticreep Composites.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025Article
- Article
- Flexible and Stretchable Pressure Sensors: From Basic Principles to State-of-the-Art Applications.Micromachines · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In this study, a flexible pressure sensor is fabricated using polydimethylsiloxane (PDMS) with a concentric circle pattern (CCP) obtained through a fused deposition modeling (FDM)-type three-dimensional (3D) printer and poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) as the active layer. Through layer-by-layer additive manufacturing, the CCP surface is generated from a thin cone model with a rough surface by the FDM-type 3D printer. A novel compression method is employed to convert the cone shape into a planar microstructure above the glass transition temperature of a polylactic acid (PLA) filament. To endow the CCP surface with conductivity, PDMS is used to replicate the compressed PLA, and PEDOT:PSS is coated by drop-casting. The size of the CCP is controlled by changing the printing layer height (PLH), which is one of the 3D printing parameters. The sensitivity increases as the PLH increases, and the pressure sensor with a 0.16 mm PLH exhibits outstanding sensitivity (160 kPa
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.