Evidence map›Paper›PMID 37032114›Full record

ArticleClinical endoscopy2023

Evaluation of the mechanical properties of current biliary self-expandable metallic stents: axial and radial force, and axial force zero border.

Wataru Yamagata, Toshio Fujisawa, Takashi Sasaki, Rei Ishibashi, Tomotaka Saito, Shuntaro Yoshida, Shizuka No, Kouta Inoue, Yousuke Nakai, Naoki Sasahira and 1 more

Abstract read
In one paragraph

Article in Clinical endoscopy, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Review
  10. Review
  11. Review
  12. Review
  13. Review
  14. Article
  15. Article
  16. Article
  17. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

11 authors.

Wataru YamagataDepartment of Gastroenterology, Graduate School of Medicine, Juntendo University, Tokyo, Japan.
Toshio FujisawaDepartment of Gastroenterology, Graduate School of Medicine, Juntendo University, Tokyo, Japan.
Takashi SasakiDepartment of Hepato-Biliary-Pancreatic Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research, Tokyo, Japan.
Rei IshibashiDepartment of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan.
Tomotaka SaitoDepartment of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan.
Shuntaro YoshidaDepartment of Endoscopy and Endoscopic Surgery, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan.
Shizuka NoMedical Laboratory, Research & Development Center, Zeon Corporation, Toyama, Japan.
Kouta InoueMedical Laboratory, Research & Development Center, Zeon Corporation, Toyama, Japan.
Yousuke NakaiDepartment of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan.
Naoki SasahiraDepartment of Hepato-Biliary-Pancreatic Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research, Tokyo, Japan.
Hiroyuki IsayamaDepartment of Gastroenterology, Graduate School of Medicine, Juntendo University, Tokyo, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND/

aimsMechanical properties (MPs) and axial and radial force (AF and RF) may influence the efficacy and complications of self-expandable metallic stent (SEMS) placement. We measured the MPs of various SEMSs and examined their influence on the SEMS clinical ability.

methodsWe evaluated the MPs of 29 types of 10-mm SEMSs. RF was measured using a conventional measurement device. AF was measured using the conventional and new methods, and the correlation between the methods was evaluated.

resultsA high correlation in AFs was observed, as measured by the new and conventional manual methods. AF and RF scatterplots divided the SEMSs into three subgroups according to structure: hook-and-cross-type (low AF and RF), cross-type (high AF and low RF), and laser-cut-type (intermediate AF and high RF). The hook-and-cross-type had the largest axial force zero border (>20°), followed by the laser-cut and cross types.

conclusionMPs were related to stent structure. Hook-and-cross-type SEMSs had a low AF and high axial force zero border and were considered safest because they caused minimal stress on the biliary wall. However, the increase in RF must be overcome.

Indexed as

Axial forceCholestasisMechanical propertyRadial forceSelf-expandable metallic stent

Identifiers

PMID37032114
PMCPMC10565432

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.