ArticleMedical engineering & physics2023
Does interpolation and intra-user variability affect the accuracy of arthrokinematic measurements in the knee? A dual fluoroscopic imaging and model-based tracking study.
Article in Medical engineering & physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Arthrokinematic Analysis of High-Impact and Large-Rotation Activities at 1 to 2 Years After Anterior Cruciate Ligament Reconstruction and Meniscal Surgery.Orthopaedic journal of sports medicine · 2026Article
- Articular Cartilage Arthrokinematics and Compositional Measurements With qMRI 1 to 2 Years After ACL Reconstruction With Meniscal Surgery.The American journal of sports medicine · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Model-based tracking (MBT) is a time-consuming and semiautomatic approach, and thus subject to errors during the tracking process. The present study aimed primarily to quantify the effects that interpolation and intra-user variability associated with MBT have on the kinematic and arthrokinematic measurements in comparison to a gold standard radiostereometric analysis (RSA). Cadaveric knee specimens were imaged at 125 Hz while simulating standing, walking, jogging, and lunging motions. (Arthro)kinematic metrics were calculated via MBT without interpolation, MBT with two interpolation techniques when every fifth or tenth frame was analyzed, and RSA. Tracking the same activity multiple times affected (p-value, largest mean difference) the flexion-extension (FE) joint angle during walking (0.03, 0.6°), and the internal-external joint angle during jogging (0.048, -0.9°). Only during jogging for the FE joint angle was there an effect of interpolation (0.046, 0.3°). Neither tracking multiple times nor interpolation affected arthrokinematic metrics (contact path locations and excursions). The present study is the first to quantify the effects that intra-user variability and interpolation have on the (arthro)kinematic measurement accuracy using MBT. Results suggest interpolation may be used without sacrificing (arthro)kinematic outcome measurement accuracy and the errors associated with intra-user variability, while small, were larger than errors due to interpolation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.