Evidence map›Paper›PMID 37028774›Full record

ArticleThe Journal of arthroplasty2023

Has Wrought Cobalt-Chromium-Molybdenum Alloy Changed for the Worse Over Time?

Stephanie M McCarthy, Deborah J Hall, Steven P Mell, Brett R Levine, Joshua J Jacobs, Robin Pourzal

Abstract read
In one paragraph

Article in The Journal of arthroplasty, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Stephanie M McCarthyRush University Medical Center, Chicago, Illinois.
Deborah J HallRush University Medical Center, Chicago, Illinois.
Steven P MellRush University Medical Center, Chicago, Illinois.
Brett R LevineRush University Medical Center, Chicago, Illinois.
Joshua J JacobsRush University Medical Center, Chicago, Illinois.
Robin PourzalRush University Medical Center, Chicago, Illinois.

Funding

Corrosion Induced Hip Implant Failure: Synergistic Interactions of Patient, Material, Design, and Surgical FactorsR01AR070181 · NIAMS · RUSH UNIVERSITY MEDICAL CENTER · PI LUNDBERG, HANNAH JEAN, MATHEW, MATHEW THOPPIL · 2016 to 2020
$2.3M
Corrosion Induced Hip Implant Failure: Synergistic Interactions of Patient, Material, Design, and Surgical FactorsR56AR070181 · NIAMS · RUSH UNIVERSITY MEDICAL CENTER · PI LUNDBERG, HANNAH JEAN, MATHEW, MATHEW THOPPIL · 2022 to 2022
$677k
NIAMS NIH HHS R01 AR070181NIAMS NIH HHS R56 AR070181
6 · The paper itself

Abstract

backgroundTotal hip arthroplasty (THA) failure due to tribocorrosion of modular junctions and resulting adverse local tissue reactions to corrosion debris have seemingly increased over the past few decades. Recent studies have found that chemically-induced column damage seen on the inner head taper is enabled by banding in the alloy microstructure of wrought cobalt-chromium-molybdenum alloy femoral heads, and is associated with more material loss than other tribocorrosion processes. It is unclear if alloy banding represents a recent phenomenon. The purpose of this study was to examine THAs implanted in the 1990s, 2000s, and 2010s to determine if alloy microstructure and implant susceptibility to severe damage has increased over time.

methodsFive hundred and forty-five modular heads were assessed for damage severity and grouped based on decade of implantation to serve as a proxy measure for manufacturing date. A subset of heads (n = 120) was then processed for metallographic analysis to visualize alloy banding.

resultsWe found that damage score distribution was consistent over the time periods, but the incidence of column damage significantly increased between the 1990s and 2000s. Banding also increased from the 1990s to 2000s, but both column damage and banding levels appear to recover slightly in the 2010s.

conclusionBanding, which provides preferential corrosion sites enabling column damage, has increased over the last 3 decades. No difference between manufacturers was seen, which may be explained by shared suppliers of bar stock material. These findings are important as banding can be avoidable, reducing the risk of severe column damage to THA modular junctions and failure due to adverse local tissue reactions.

Indexed as

Arthroplasty, Replacement, HipHip ProsthesisChromium AlloysCobaltCorrosionFemur HeadHumansProsthesis DesignProsthesis FailureVitalliumChromium AlloysCobaltVitalliumCoCrMoimplant alloysimplant materialsimplant metallurgytotal hip arthroplasty

Identifiers

PMID37028774
PMCPMC10330267

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.