ArticleClinical and experimental dental research2023
An in vitro study evaluating the efficacy of a novel mount with torque control designed to tighten Osstell® transducers.
Article in Clinical and experimental dental research, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 5 citations in OpenAlex.
- The Effect of Osseodensification on Implant Stability and Marginal Bone Levels: A Randomized Control Clinical Trial.Clinical and experimental dental research · 2025Trial
- Dental Implants Placed in Fresh Human Extraction Sockets Without Osteotomy: A Case Series.Clinical and experimental dental research · 2025Article
- An In Vitro Evaluation of Periotest Implant Stability Measurements Taken on Implant Retained Crowns and Healing Abutments.Clinical and experimental dental research · 2024Article
- A longitudinal analysis of the impact of nonsurgical and surgical treatment of peri-implantitis upon clinical parameters and implant stability quotient values. A 2-3-year follow-up.Clinical and experimental dental research · 2024Article
- An in vitro study evaluating the efficacy of a novel mount with torque control designed to tighten Osstell® transducers.Clinical and experimental dental research · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesTo evaluate the efficacy of a novel mount with torque control for tightening of Osstell® transducers and to determine the reliability of recorded ISQ measurements from implants placed in various bone densities. MATERIAL AND
methodsFifty-six implants, comprising seven different implant types, were placed in eight polyurethane blocks representing D1, D2, D3, and D4 bone densities. Resonance frequency analysis (RFA) transducers were attached to each implant in four different ways: (a) hand tightening, (b) hand tightening with a SmartPeg Mount™, (c) hand tightening using the novel mount with torque control (SafeMount) and (d) tightening to 6 Ncm with a calibrated torque device. ISQ measurements were taken and a second operator repeated the measurements. Intraclass correlation coefficient (ICC) was calculated to assess the reliability of the measurements and linear mixed effects regression was employed to determine the effect explanatory variables had on ISQ values.
resultsThere was a statistically significant difference in ISQ values obtained by hand tightening transducers compared to the calibrated torque device p < .001, 95%(-2.89, -1.21) but not between any other tightening methods. There was excellent agreement between the two RFA devices (ICC 0.986) and between buccal and mesial measurements (ICC 0.977). For all transducer tightening methods there was excellent inter-operator agreement in D1 and D2 (ICC > 0.8) but very poor agreement in D4 (ICC < 0.24). Bone density accounted for 36% of the variation in ISQ values, the implant for 11% and the operator for 6%.
conclusionsSafeMount, did not significantly improve the reliability of the RFA measurements when compared to the standard mount, but calibrated torque devices seem to have benefits when compared to tightening the transducers by hand. Results also indicate that the ISQ values should be interpreted with caution when measuring implant stability in poor quality bone regardless of the implant geometry.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.