ArticleIEEE microwave and wireless technology letters2023
Design and Implementation of Multisite Stimulation System Using a Double-Tuned Transmitter Coil and Miniaturized Implants.
Article in IEEE microwave and wireless technology letters, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- A closed loop fully automated wireless vagus nerve stimulation system.Scientific reports · 2025Article
- Miniaturized Wirelessly Powered and Controlled Implants for Multisite Stimulation.IEEE transactions on microwave theory and techniques · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
This letter presents a double-tuned dual input transmitter coil operating at 13.56 MHz and 40.68 MHz industrial, scientific, and medical (ISM) bands for multisite biomedical applications. The proposed system removes the need for two separate coils, which reduces system size and unwanted couplings. The design and analysis of the double-tuned transmitter coil using a lumped element frequency trap are discussed in this letter. The transmitter achieves measured matching of -26.2 dB and -21.5 dB and isolation of -17.7 dB and -11.7dB at 13.56 MHz and 40.68 MHz, respectively. A 3 mm × 15 mm flexible coil is used as an implantable receiver. This letter shows synchronized multisite stimulation of two flexible implants at a distance of 2 cm while covered with 1 cm chicken breast.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials