Evidence map›Paper›PMID 37025069›Full record

ArticleJournal of applied clinical medical physics2023

Simultaneous spatial and temporal regularization in low-dose dynamic contrast-enhanced CT cerebral perfusion studies.

Kenya Murase, Atsushi Nakamoto, Noriyuki Tomiyama

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Kenya MuraseDepartment of Future Diagnostic Radiology, Graduate School of Medicine, Osaka University, Suita, Osaka, Japan.
Atsushi NakamotoDepartment of Future Diagnostic Radiology, Graduate School of Medicine, Osaka University, Suita, Osaka, Japan.
Noriyuki TomiyamaDepartment of Diagnostic and Interventional Radiology, Graduate School of Medicine, Osaka University, Suita, Osaka, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo apply total generalized variation (TGV) and its combination with low-rank and sparse decomposition (LRSD) (LTGV) to cerebral perfusion studies using low-dose dynamic contrast-enhanced (DCE) CT and to quantitatively evaluate their performances through comparisons with those without any regularizers and those of total variation (TV) and its combination with LRSD (LTV) using simulation and clinical data.

methodsThe simulation study used a realistic digital brain phantom. Low-dose DCE-CT images were reconstructed using the regularizers and primal-dual algorithm. Subsequently, cerebral perfusion parameter (CPP) images were generated from them. Thereafter, their quality was evaluated based on the peak signal-to-noise ratio (PSNR) and structural similarity index measure (SSIM). Further, the accuracy of CPP estimation was evaluated through a linear regression analysis between the CPP values obtained by the above regularizers and those obtained from the noise-free DCE-CT images. In addition, the mean and standard deviation of the CPP were calculated (region analysis). In the clinical study, low-dose DCE-CT images were generated using normal-dose images acquired from a patient, and CPP images were generated from them similar to that in the simulation study.

resultsWhen using LTV and LTGV, both PSNR and SSIM were higher than those of the other methods with increasing regularization parameter values. The results of the linear regression and region analyses demonstrated that TGV generally exhibited the best performance, followed by LTGV, and finally that of TV was significantly different from those of the other regularizers. Despite an overall consistency between the simulation and clinical results, certain inconsistencies appeared owing to the difference in generating low-dose DCE-CT images.

conclusionsThe results implied that TGV and LTGV were useful in improving the accuracy of CPP estimation using low-dose DCE-CT. This study provides an improved understanding of the performance of regularizers and is expected to aid in the selection of a suitable regularizer for low-dose DCE-CT perfusion studies.

Indexed as

Image Processing, Computer-AssistedTomography, X-Ray ComputedAlgorithmsBrainCerebrovascular CirculationHumansPhantoms, ImagingSignal-To-Noise Ratiocerebral perfusion studylow-dose dynamic contrast-enhanced CTlow-rank and sparse decompositionsimultaneous spatial and temporal regularizationtotal generalized variationtotal variation

Identifiers

PMID37025069
PMCPMC10243341

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.