ArticleScientific reports2023
Accurate real space iterative reconstruction (RESIRE) algorithm for tomography.
Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
18 citing papers in PubMed.
- Feasibility of longitudinal in vivo monitoring of pulmonary disease progression in mouse models using laboratory-based x-ray dark-field CT.European radiology experimental · 2026Article
- Deep learning for scalable atomic electron tomography.National science review · 2026Article
- Crystal nucleation and growth in high-entropy alloys revealed by atomic electron tomography.Nature materials · 2026Article
- Annulus fracture underlies radiation-induced sperm dysfunction revealed by multimodal nano-imaging.Life science alliance · 2026Article
- A general data-driven framework for scalable electron tomography.National science review · 2026Article
- Generative-model-based null-space iterative reconstruction for atomic electron tomography with sparse data.Nature communications · 2026Article
- Article
- Article
- Upgrade of the Coherent X-ray Scattering beamline at Pohang Light Source II.Journal of synchrotron radiation · 2026Article
- PhaseT3M: 3D imaging at 1.6 Å resolution via electron cryo-tomography with nonlinear phase retrieval.Nature communications · 2025Article
- Three-dimensional network of multi-fold twins enabled by geometrically necessary amorphous zones.Nature communications · 2025Article
- Octo-diamond crystal of nanoscale tetrahedra with interchanging chiral motifs.Nature materials · 2025Article
- Review
- Three-dimensional atomic insights into the metal-oxide interface in Zr-ZrONature communications · 2024Article
- Seeing the Supracolloidal Assemblies in 3D: Unraveling High-Resolution Structures Using Electron Tomography.ACS materials Au · 2024Review
- Real space iterative reconstruction for vector tomography (RESIRE-V).Scientific reports · 2024Article
- Three-dimensional atomic structure and local chemical order of medium- and high-entropy nanoalloys.Nature · 2023Article
- Maximum Lyapunov exponent-based multiple chaotic slime mold algorithm for real-world optimization.Scientific reports · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Tomography has made a revolutionary impact on the physical, biological and medical sciences. The mathematical foundation of tomography is to reconstruct a three-dimensional (3D) object from a set of two-dimensional (2D) projections. As the number of projections that can be measured from a sample is usually limited by the tolerable radiation dose and/or the geometric constraint on the tilt range, a main challenge in tomography is to achieve the best possible 3D reconstruction from a limited number of projections with noise. Over the years, a number of tomographic reconstruction methods have been developed including direct inversion, real-space, and Fourier-based iterative algorithms. Here, we report the development of a real-space iterative reconstruction (RESIRE) algorithm for accurate tomographic reconstruction. RESIRE iterates between the update of a reconstructed 3D object and the measured projections using a forward and back projection step. The forward projection step is implemented by the Fourier slice theorem or the Radon transform, and the back projection step by a linear transformation. Our numerical and experimental results demonstrate that RESIRE performs more accurate 3D reconstructions than other existing tomographic algorithms, when there are a limited number of projections with noise. Furthermore, RESIRE can be used to reconstruct the 3D structure of extended objects as demonstrated by the determination of the 3D atomic structure of an amorphous Ta thin film. We expect that RESIRE can be widely employed in the tomography applications in different fields. Finally, to make the method accessible to the general user community, the MATLAB source code of RESIRE and all the simulated and experimental data are available at https://zenodo.org/record/7273314 .
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.