ArticleTexas Heart Institute journal2023
Coronary Stent Off-Wire Dislodgement: Case Report of a Rare Complication.
Article in Texas Heart Institute journal, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 2 citations in OpenAlex.
- Stent Crumpling as a Complication of Percutaneous Coronary Intervention, a Case Report and Literature Review.Clinical case reports · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Although several techniques have been reported for managing an on-wire dislodged stent in the coronary artery, very few reports have focused on the much rarer complication of an off-wire dislodged stent. In a 73-year-old man who experienced an off-wire dislodged coronary stent, the proximal elongated segment was lodged in the left main coronary artery, and the distal segment was floating in the aorta like a wind sock. After a failed attempt at retrieval using a gooseneck microsnare, the dislodged stent was successfully removed using a 3-loop vascular snare via the left radial artery. There was no obvious vascular injury. This novel technique for removing a partially floating dislodged stent was successful after conventional retrieval techniques failed.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.