Evidence map›Paper›PMID 37022612›Full record

ArticlePhysical and engineering sciences in medicine2023

Correction factors for commissioning and patient specific quality assurance of stereotactic fields in a Monte Carlo based treatment planning system : TPS correction factors.

Simon K Goodall, Pejman Rowshanfarzad, Martin A Ebert

Abstract read
In one paragraph

Article in Physical and engineering sciences in medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Simon K GoodallSchool of Physics, Mathematics, and Computing, The University of Western Australia, Crawley, WA, 6009, Australia. Simon.goodall@genesiscare.com.ORCID http://orcid.org/0000-0003-3318-9703
Pejman RowshanfarzadSchool of Physics, Mathematics, and Computing, The University of Western Australia, Crawley, WA, 6009, Australia.ORCID http://orcid.org/0000-0001-8306-7742
Martin A EbertSchool of Physics, Mathematics, and Computing, The University of Western Australia, Crawley, WA, 6009, Australia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Validation of small field dosimetry is crucial for stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT). Accurate and considered measurement of linear accelerator dose must be compared to precise and accurate calculation by the treatment planning system (TPS). Monte Carlo calculated distributions contain statistical noise, reducing the reliance that should be given to single voxel doses. The average dose to a small volume of interest (VOI) can minimise the influence of noise, but for small fields introduces significant volume averaging. Similar challenges present during measurement of composite dose from clinical plans when a small volume ionisation chamber is used. This study derived correction factors for VOI averaged TPS doses calculated for small fields, allowing correction to an isocentre dose following account for statistical noise. These factors were used to determine an optimal VOI to represent small volume ionisation chambers during patient specific quality assurance (PSQA). A retrospective comparison of 82 SRS and 28 SBRT PSQA measurements to TPS calculated doses from varying VOI was completed to evaluate the determined volumes. Small field commissioning correction factors of under 5% were obtained for field sizes of 8 mm and larger. Optimal spherical VOI with radius between 1.5 and 1.8 mm and 2.5 to 2.9 mm were determined for IBA CC01 and CC04 ionisation chambers respectively. Review of PSQA confirmed an optimal agreement between CC01 measured doses and a volume of 1.5 to 1.8 mm while CC04 measured doses showed no variation with VOI.

Indexed as

RadiosurgeryRadiotherapy Planning, Computer-AssistedHumansParticle AcceleratorsRadiotherapy DosageRetrospective StudiesCorrection factorsIonisation chamber measurmentsPatient Specific Quality AssurancePSQASBRT QASRS QA

Identifiers

PMID37022612
PMCPMC10209265

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.