Evidence map›Paper›PMID 37018086›Full record

ArticleIEEE transactions on ultrasonics, ferroelectrics, and frequency control2023

Passive Cavitation Imaging Artifact Reduction Using Data-Adaptive Spatial Filtering.

Kevin J Haworth, Nuria Gonzales Salido, Maxime Lafond, Daniel Suarez Escudero, Christy K Holland

Abstract read
In one paragraph

Article in IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Assessment of Cavitation From DEFINITY and DEFINITY RT.Ultrasound in medicine & biology · 2026
    Article
  2. Passive cavitation imaging with pMedical physics · 2026
    Article
  3. Article
  4. Enhancing Passive Cavitation Imaging Using pIEEE transactions on bio-medical engineering · 2025
    Article
  5. Overview of Therapeutic Ultrasound Applications and Safety Considerations: 2024 Update.Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2025
    Review
  6. Article
  7. Article
  8. Contrast-Enhanced Imaging of Histotripsy Bubble Clouds Using Chirp-Coded Excitation and Volterra Filtering.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Kevin J Haworth
Nuria Gonzales Salido
Maxime Lafond
Daniel Suarez Escudero
Christy K Holland

Funding

Echogenic Targeted Liposomes: Transfection/Drug DeliveryR01HL135092 · NHLBI · UNIVERSITY OF TEXAS HLTH SCI CTR HOUSTON · PI David D McPherson · 2017 to 2026
$5.0M
Targeted Liposomes for Acoustic Cardiovascular ImagingR56HL059586 · NHLBI · UNIVERSITY OF TEXAS HLTH SCI CTR HOUSTON · PI MCPHERSON, DAVID D · 2008 to 2008
$480k
NHLBI NIH HHS R01 HL135092NHLBI NIH HHS R56 HL059586
6 · The paper itself

Abstract

Passive cavitation imaging (PCI) with a clinical diagnostic array results in poor axial localization of bubble activity due to the size of the point spread function (PSF). The objective of this study was to determine if data-adaptive spatial filtering improved PCI beamforming performance relative to standard frequency-domain delay, sum, and integrate (DSI) or robust Capon beamforming (RCB). The overall goal was to improve source localization and image quality without sacrificing computation time. Spatial filtering was achieved by applying a pixel-based mask to DSI- or RCB-beamformed images. The masks were derived from DSI, RCB, or phase or amplitude coherence factors (ACFs) using both receiver operating characteristic (ROC) and precision-recall (PR) curve analyses. Spatially filtered passive cavitation images were formed from cavitation emissions based on two simulated sources densities and four source distribution patterns mimicking cavitation emissions induced by an EkoSonic catheter. Beamforming performance was assessed via binary classifier metrics. The difference in sensitivity, specificity, and area under the ROC curve (AUROC) differed by no more than 11% across all algorithms for both source densities and all source patterns. The computational time required for each of the three spatially filtered DSIs was two orders of magnitude less than that required for time-domain RCB and thus this data-adaptive spatial filtering strategy for PCI beamforming is preferable given the similar binary classification performance.

Identifiers

PMID37018086
PMCPMC10335845

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.