Evidence map›Paper›PMID 37016247›Full record

ArticleAbdominal radiology (New York)2023

Reference values for 4D flow magnetic resonance imaging of the portal venous system.

Andrew Huang, Grant S Roberts, Alejandro Roldán-Alzate, Oliver Wieben, Scott B Reeder, Thekla H Oechtering

Open access · greenAbstract read
In one paragraph

Article in Abdominal radiology (New York), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.8field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 9 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 2 countries.

Andrew HuangDepartment of Radiology, University of Wisconsin, Madison, WI, USA.ORCID http://orcid.org/0000-0001-7543-8136
Grant S RobertsDepartment of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, WI, USA.ORCID http://orcid.org/0000-0003-1472-4352
Alejandro Roldán-AlzateDepartment of Mechanical Engineering, University of Wisconsin, Madison, WI, USA.ORCID http://orcid.org/0000-0003-4149-4038
Oliver WiebenDepartment of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, WI, USA.ORCID http://orcid.org/0000-0002-7931-1930
Scott B ReederDepartment of Radiology, University of Wisconsin, Madison, WI, USA.ORCID http://orcid.org/0000-0003-4728-8171
Thekla H OechteringDepartment of Radiology, University of Wisconsin, Madison, WI, USA. oechtering@wisc.edu.ORCID http://orcid.org/0000-0002-1931-1912
University of Wisconsin–Madison · US

Funding

Development of 4D Flow MRI for Risk Stratification of Variceal Bleeding in CirrhosisR01DK125783 · NIDDK · UNIVERSITY OF WISCONSIN-MADISON · PI REEDER, SCOTT B., WIEBEN, OLIVER · 2021 to 2024
$2.2M
NIDDK NIH HHS R01 DK125783NIH HHS R01 DK125783
6 · The paper itself

Abstract

purposeThe purpose of this work was to establish normal reference values for 4D flow MRI-derived flow, velocity, and vessel diameters, and to define characteristic flow patterns in the portal venous system of healthy adult subjects.

methodsFor this retrospective study, we screened all available 4D flow MRI exams of the upper abdomen in healthy adults acquired at our institution between 2012 and 2022 at either 1.5 T or 3.0 T MRI after ≥ 5 h fasting. Flow, velocity, and effective diameter were quantified in the 8 planes in the portal venous system (splenic vein, superior mesenteric vein, main, right, and left portal veins). Vessel delineation was manually adjusted over time. Reference ranges for were defined as the mean ± 2 standard deviations. Three readers noted helical and vortical flow on time-resolved pathline visualizations. Conservation of mass flow analysis was performed for quality assurance.

resultsWe included 44 healthy subjects (26 female, 18-74 years) in the analysis. We report reference values for mean and peak flow, mean velocity, and vessel diameter in the healthy portal vein using 4D flow MRI. Normal flow patterns in the portal vein included faint helical (66%) or linear flow (34%). Conservation of mass analysis demonstrated a relative error of 1.1 ± 4.6% standard deviation (SD) at the splenomesenteric confluence and - 1.4 ± 4.1% SD at the portal bifurcation.

conclusionWe have reported normal hemodynamic values that are necessary baseline data for emerging clinical applications of 4D flow MRI in the portal venous system. Results are consistent with previously published values from smaller cohorts.

Indexed as

AbdomenMagnetic Resonance ImagingAdultBlood Flow VelocityFemaleHumansImaging, Three-DimensionalPortal VeinReference ValuesRetrospective Studies4D flow MRIPortal hypertensionPortal veinReference values

Identifiers

PMID37016247
PMCPMC10518803
OpenAlexW4362548984

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.