Evidence map›Paper›PMID 37015676›Full record

ArticleIEEE transactions on bio-medical engineering2023

PIRET-A Platform for Treatment Planning in Electroporation-Based Therapies.

Enric Perera-Bel, Kenneth N Aycock, Zaid S Salameh, Mario Gomez-Barea, Rafael V Davalos, Antoni Ivorra, Miguel A Gonzalez Ballester

Abstract read
In one paragraph

Article in IEEE transactions on bio-medical engineering, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Reversible electroporation for cancer therapy.The British journal of radiology · 2025
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Enric Perera-Bel
Kenneth N Aycock
Zaid S Salameh
Mario Gomez-Barea
Rafael V Davalos
Antoni Ivorra
Miguel A Gonzalez Ballester

Funding

Development and application of non-thermal high frequency IRE to treat hepatic tumorsR01CA240476 · NCI · VIRGINIA POLYTECHNIC INST AND ST UNIV · PI DAVALOS, RAFAEL VIDAL · 2020 to 2024
$2.2M
High-frequency Irreversible Electroporation (H-FIRE) combinatorial GBM treatmentR01CA213423 · NCI · VIRGINIA POLYTECHNIC INST AND ST UNIV · PI DAVALOS, RAFAEL VIDAL, VERBRIDGE, SCOTT S · 2017 to 2021
$1.7M
NCI NIH HHS R01 CA213423NCI NIH HHS R01 CA240476
6 · The paper itself

Abstract

Tissue electroporation is the basis of several therapies. Electroporation is performed by briefly exposing tissues to high electric fields. It is generally accepted that electroporation is effective where an electric field magnitude threshold is overreached. However, it is difficult to preoperatively estimate the field distribution because it is highly dependent on anatomy and treatment parameters.

objectiveWe developed PIRET, a platform to predict the treatment volume in electroporation-based therapies.

methodsThe platform seamlessly integrates tools to build patient-specific models where the electric field is simulated to predict the treatment volume. Patient anatomy is segmented from medical images and 3D reconstruction aids in placing the electrodes and setting up treatment parameters.

resultsFour canine patients that had been treated with high-frequency irreversible electroporation were retrospectively planned with PIRET and with a workflow commonly used in previous studies, which uses different general-purpose segmentation (3D Slicer) and modeling software (3Matic and COMSOL Multiphysics). PIRET outperformed the other workflow by 65 minutes (× 1.7 faster), thanks to the improved user experience during treatment setup and model building. Both approaches computed similarly accurate electric field distributions, with average Dice scores higher than 0.93.

conclusionA platform which integrates all the required tools for electroporation treatment planning is presented. Treatment plan can be performed rapidly with minimal user interaction in a stand-alone platform. SIGNIFICANCE: This platform is, to the best of our knowledge, the most complete software for treatment planning of irreversible electroporation. It can potentially be used for other electroporation applications.

Indexed as

ElectrochemotherapyAnimalsDogsElectroporationElectroporation TherapiesRetrospective StudiesSoftware

Identifiers

PMID37015676
PMCPMC10281020

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.