Evidence map›Paper›PMID 37014879›Full record

ArticlePloS one2023

ECG signal classification in wearable devices based on compressed domain.

Jing Hua, Binbin Chu, Jiawen Zou, Jing Jia

Abstract read
In one paragraph

Article in PloS one, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Jing HuaSchool of Software, Jiangxi Agricultural University, Nanchang, China.
Binbin ChuSchool of Computer and Information Engineering, Jiangxi Agricultural University, Nanchang, China.ORCID 0000-0003-3636-1388
Jiawen ZouSchool of Computer and Information Engineering, Jiangxi Agricultural University, Nanchang, China.
Jing JiaSchool of Software, Jiangxi Agricultural University, Nanchang, China.ORCID 0000-0002-0680-7660

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Wearable devices are often used to diagnose arrhythmia, but the electrocardiogram (ECG) monitoring process generates a large amount of data, which will affect the detection speed and accuracy. In order to solve this problem, many studies have applied deep compressed sensing (DCS) technology to ECG monitoring, which can under-sampling and reconstruct ECG signals, greatly optimizing the diagnosis process, but the reconstruction process is complex and expensive. In this paper, we propose an improved classification scheme for deep compressed sensing models. The framework is comprised of four modules: pre-processing; compression; and classification. Firstly, the normalized ECG signals are compressed adaptively in the three convolutional layers, and then the compressed data is directly put into the classification network to obtain the results of four kinds of ECG signals. We conducted our experiments on the MIT-BIH Arrhythmia Database and Ali Cloud Tianchi ECG signal Database to validate the robustness of our model, adopting Accuracy, Precision, Sensitivity and F1-score as the evaluation metrics. When the compression ratio (CR) is 0.2, our model has 98.16% accuracy, 98.28% average accuracy, 98.09% Sensitivity and 98.06% F1-score, all of which are better than other models.

Indexed as

Data CompressionWearable Electronic DevicesAlgorithmsArrhythmias, CardiacElectrocardiographyHumansSignal Processing, Computer-Assisted

Identifiers

PMID37014879
PMCPMC10072459

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.