Evidence map›Paper›PMID 37014837›Full record

ArticlePloS one2023

Validation of direct CT measurement of malrotation in femoral neck fractures: A bone model study.

Emmanouil Liodakis, Gesa Helen Pöhler, Lena Sonnow, Philipp Mommsen, Jan-Dierk Clausen, Tilman Graulich, Alexander Maslaris, Mohamed Omar, Timo Stübig, Stephan Sehmisch and 1 more

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.0field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 2 institutions in 1 country.

Emmanouil LiodakisTrauma Department, Hannover Medical School (MHH), Lower Saxony, Germany.
Gesa Helen PöhlerDepartment of Radiology, Hannover Medical School (MHH), Lower Saxony, Germany.
Lena SonnowDepartment of Radiology, Hannover Medical School (MHH), Lower Saxony, Germany.
Philipp MommsenTrauma Department, Hannover Medical School (MHH), Lower Saxony, Germany.
Jan-Dierk ClausenTrauma Department, Hannover Medical School (MHH), Lower Saxony, Germany.
Tilman GraulichTrauma Department, Hannover Medical School (MHH), Lower Saxony, Germany.
Alexander MaslarisDepartment of Orthopaedics and Trauma Surgery, Alfried Krupp Hospital, Campus Rüttenscheid, Essen, Germany.
Mohamed OmarTrauma Department, Hannover Medical School (MHH), Lower Saxony, Germany.
Timo StübigTrauma Department, Hannover Medical School (MHH), Lower Saxony, Germany.
Stephan SehmischTrauma Department, Hannover Medical School (MHH), Lower Saxony, Germany.
Tarek Omar PachaTrauma Department, Hannover Medical School (MHH), Lower Saxony, Germany.ORCID 0000-0002-3542-5098
Medizinische Hochschule Hannover · DEAlfried Krupp Hospital · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundWhile postoperative malrotation in the subtrochanteric region is a well-known problem, malrotation after osteosynthesis in proximal femoral fractures has not been extensively studied. In this context, many methods for perioperatively assessment of femoral torsion have been described, but none of them is applicable in the basicervical region of the proximal femur. As an important difference in femoral neck fractures, the discontinuous neck fails to serve as a significant "pointer" for measurements and malfunctions to be placed in relation to the condylar plane. Considering postoperative maltorsion at any location as a substantial negative effect on patients' outcome and functional expectations, precise and patient-friendly rotation measurement standards in femoral neck fractures are desired in clinical practice. Recently, a novel computed tomography (CT) based geometric technique was described named "direct measurement" with promising results covering this diagnostic disparity, but still requires validation. Thus, we aimed to validate the previously described technique using a controlled range of displacement in a femoral neck fracture Sawbone® model. METHODS AND

findingsA goniometer was designed to set retro- and anteversion of the proximal femur in a reproducible manner. Prospectively, all femurs underwent a CT scan and were measured 3D for displacement. The interclass correlation between the CT measurements and the goniometer measurements was calculated and was found to be very high (1.00, 95% confidence interval: 0.99-1.00; p < 0.001). For the mean of all measurements, the Pearson's correlation was 1.00 (p < 0.001). No significant differences in the measurements of both investigators were observed, with 20° of retroversion not significant (-1.20 ± 1.71; 95% confidence interval: -2.43-0.03; p = 0.054).

conclusionThis CT-based 3D measurement technique may allow for perioperative malrotation assessment in basicervical femoral neck fractures and appears to be feasible in femoral neck fractures when it comes to rare cases of osteosynthesis. Further investigations are still needed to define the thresholds of malrotation provoking functional impairment after osteosynthesis in basicervical femoral neck fractures.

Indexed as

Femoral FracturesFemoral Neck FracturesFemurFracture Fixation, InternalHumansTomography, X-Ray Computed

Identifiers

PMID37014837
PMCPMC10072492
OpenAlexW4362521104

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.