Evidence map›Paper›PMID 37012526›Full record

ArticleMikrochimica acta2023

Incorporation of carbon black into a sonogel matrix: improving antifouling properties of a conducting polymer ceramic nanocomposite.

Alfonso Sierra-Padilla, David López-Iglesias, Paloma Calatayud-Macías, Juan José García-Guzmán, José María Palacios-Santander, Laura Cubillana-Aguilera

Open access · hybridAbstract read
In one paragraph

Article in Mikrochimica acta, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
2.2field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 21 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Alfonso Sierra-PadillaDepartment of Analytical Chemistry, Institute of Research on Electron Microscopy and Materials (IMEYMAT), Faculty of Sciences, Campus de Excelencia Internacional del Mar (CEIMAR), University of Cadiz, Campus Universitario de Puerto Real, Polígono del Río San Pedro S/N, 11510, Puerto Real, Cadiz, Spain.ORCID https://orcid.org/0000-0002-7353-7971
David López-IglesiasInstituto de Investigación e Innovación Biomédica de Cadiz (INiBICA), Hospital Universitario 'Puerta del Mar', Universidad de Cadiz, 11009, Cadiz, Spain.ORCID https://orcid.org/0000-0001-8278-6585
Paloma Calatayud-MacíasDepartment of Analytical Chemistry, Institute of Research on Electron Microscopy and Materials (IMEYMAT), Faculty of Sciences, Campus de Excelencia Internacional del Mar (CEIMAR), University of Cadiz, Campus Universitario de Puerto Real, Polígono del Río San Pedro S/N, 11510, Puerto Real, Cadiz, Spain.
Juan José García-GuzmánInstituto de Investigación e Innovación Biomédica de Cadiz (INiBICA), Hospital Universitario 'Puerta del Mar', Universidad de Cadiz, 11009, Cadiz, Spain.ORCID https://orcid.org/0000-0002-3124-0141
José María Palacios-SantanderDepartment of Analytical Chemistry, Institute of Research on Electron Microscopy and Materials (IMEYMAT), Faculty of Sciences, Campus de Excelencia Internacional del Mar (CEIMAR), University of Cadiz, Campus Universitario de Puerto Real, Polígono del Río San Pedro S/N, 11510, Puerto Real, Cadiz, Spain. josem.palacios@uca.es.ORCID http://orcid.org/0000-0001-5407-1208
Laura Cubillana-AguileraDepartment of Analytical Chemistry, Institute of Research on Electron Microscopy and Materials (IMEYMAT), Faculty of Sciences, Campus de Excelencia Internacional del Mar (CEIMAR), University of Cadiz, Campus Universitario de Puerto Real, Polígono del Río San Pedro S/N, 11510, Puerto Real, Cadiz, Spain.ORCID https://orcid.org/0000-0002-3559-2697
Universidad de Cádiz · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A new electrochemical sensor device has been developed through the modification of a polyaniline-silicon oxide network with carbon black (CB). Enhanced electrical conductivity and antifouling properties have been achieved due to the integration of this cheap nanomaterial into the bulk of the sensor. The structure of the developed material was characterized using Fourier transform infrared spectroscopy, energy-dispersive X-ray spectroscopy, and scanning electron microscopy techniques. Cyclic voltammetry was used to characterize electrochemically the Sonogel-Carbon/Carbon Black-PANI (SNG-C/CB-PANI) sensor device. In addition, differential pulse voltammetry was employed to evaluate the analytical response of the sensor towards sundry chlorophenols, common environmental hazards in aqueous ecosystems. The modified sensor material showed excellent antifouling properties, which led to a better electroanalytical performance than the one displayed with the bare sensor. Notably, a sensitivity of 5.48 × 10

Indexed as

Antifouling propertiesChlorophenolsConducting polymersHigh-energy ultrasoundNanomaterialsSonogel-Carbon electrochemical sensors; Differential pulse voltammetry

Identifiers

PMID37012526
PMCPMC10070287
OpenAlexW4362523499

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.