Evidence map›Paper›PMID 37009578›Full record

ArticleJournal of biomedical optics2023

Evaluating clinical near-infrared surgical camera systems with a view to optimizing operator and computational signal analysis.

Jeffrey Dalli, Abhinav Jindal, Gareth Gallagher, Jonathan P Epperlein, Niall P Hardy, Ra'ed Malallah, Kilian O'Donoghue, Padraig Cantillon-Murphy, Pól G Mac Aonghusa, Ronan A Cahill

Full text readEvaluation Study
In one paragraph

Article in Journal of biomedical optics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Review
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Jeffrey DalliUniversity College, UCD Centre for Precision Surgery, Dublin, Ireland.ORCID 0000-0003-0170-3667
Abhinav JindalUniversity College, UCD Centre for Precision Surgery, Dublin, Ireland.ORCID 0000-0003-1953-4910
Gareth GallagherUniversity College, UCD Centre for Precision Surgery, Dublin, Ireland.
Jonathan P EpperleinIBM Research Europe, Dublin, Ireland.ORCID 0000-0003-2912-0543
Niall P HardyUniversity College, UCD Centre for Precision Surgery, Dublin, Ireland.
Ra'ed MalallahUniversity College, UCD Centre for Precision Surgery, Dublin, Ireland.ORCID 0000-0003-1268-780X
Kilian O'DonoghueUniversity College Cork, School of Engineering, Cork, Ireland.
Padraig Cantillon-MurphyUniversity College Cork, School of Engineering, Cork, Ireland.
Pól G Mac AonghusaIBM Research Europe, Dublin, Ireland.ORCID 0000-0002-7640-9668
Ronan A CahillUniversity College, UCD Centre for Precision Surgery, Dublin, Ireland.ORCID 0000-0002-1270-4000

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Significance: As clinical evidence on the colorectal application of indocyanine green (ICG) perfusion angiography accrues, there is also interest in computerizing decision support. However, user interpretation and software development may be impacted by system factors affecting the displayed near-infrared (NIR) signal. Aim: We aim to assess the impact of camera positioning on the displayed NIR signal across different open and laparoscopic camera systems. Approach: The effects of distance, movement, and target location (center versus periphery) on the displayed fluorescence signal of different systems were measured under electromagnetic stereotactic guidance from an ICG-albumin model and Results: Systems displayed distinct fluorescence performances with variance apparent with scope optical lens configuration (0 deg versus 30 deg), movement, target positioning, and distance. Laparoscopic system readings fitted inverse square function distance-intensity curves with one device and demonstrated a direction dependent sigmoid curve. Laparoscopic cameras presented central targets as brighter than peripheral ones, and laparoscopes with angled optical lens configurations had a diminished field of view. One handheld open system also showed a distance-intensity relationship, whereas the other maintained a consistent signal despite distance, but both presented peripheral targets brighter than central ones. Conclusions: Optimal clinical use and signal computational development requires detailed appreciation of system behaviors.

Indexed as

Indocyanine GreenLaparoscopyAngiographyFluorescenceSpectroscopy, Near-InfraredIndocyanine Greenanastomosisfluorescence angiographyindocyanine greenlaparoscopynear-infrared

Identifiers

PMID37009578
PMCPMC10050972

What OpenQuestion holds

Textfull text, public
LicenceCC BY
measurements read34
identifiers read1
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.