Evidence map›Paper›PMID 37005637›Full record

ArticleJournal of orthopaedic surgery and research2023

Significantly reducing the presurgical preparation time for anterior pelvic fracture surgery by faster creating patient-specific curved plates.

Sendren Sheng-Dong Xu, Tsu-Te Yeh, Jia-En Chen, Yuan-Ta Li

Open access · goldAbstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.6field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 1 country.

Sendren Sheng-Dong XuGraduate Institute of Automation and Control, National Taiwan University of Science and Technology, No. 43, Keelung Rd., Sec. 4, Da'an Dist., Taipei City, 106335, Taiwan.
Tsu-Te YehDepartment of Orthopedic Surgery, Tri-Service General Hospital, National Defense Medical Center, No. 325, Chenggong Rd., Sec. 2, Neihu Dist., Taipei City, 114202, Taiwan. tsutey@gmail.com.
Jia-En ChenGraduate Institute of Automation and Control, National Taiwan University of Science and Technology, No. 43, Keelung Rd., Sec. 4, Da'an Dist., Taipei City, 106335, Taiwan.
Yuan-Ta LiDepartment of Orthopedic Surgery, Tri-Service General Hospital, National Defense Medical Center, No. 325, Chenggong Rd., Sec. 2, Neihu Dist., Taipei City, 114202, Taiwan.
National Taiwan University of Science and Technology · TWNational Defense Medical Center · TWTri-Service General Hospital · TW

Funding

National Taiwan University of Science and Technology Grant TSGH-NTUST-109-04The Ministry of Science and Technology (MOST), Taiwan Grants MOST 109-2221-E-011-074, MOST 110-2221-E-011-121, and MOST 111-2221-E-011-146-MY2.The Tri-Service General Hospital, Taiwan Grants TSGH-D-110105, TSGH-B-110008, MND-MAB-110-016, TSGH-NTUST-109-04, TSGH-A-109004, TSGH-B-109007, TSGH-C108-001, MAB-108-034, MND-MAB-C-11109-111035, and TSGH-C107-001.
6 · The paper itself

Abstract

backgroundTo shorten the preoperative preparation time, reconstruction plates were designed using the computed tomography (CT)-based three-dimensional (3D) medical imaging surgical planning software OOOPDS. In addition, 3D printing was used to generate curved plates for anterior pelvic fracture surgeries.

methodsThis study analyzed two groups with the same 21 patients who underwent surgery for traumatic anterior pelvic ring fractures. In Group 1, the direct reconstruction plates were preoperatively contoured according to the anatomical 3D-printed pelvic model. In Group 2, the fixation plates were contoured according to the 3D printed plate templates, which were created based on the simulated plate templates by the OOOPDS software. The processing time, including the 3D printing time for the pelvic models in Group 1, the 3D printing time for the fixation plate templates in Group 2, and the pre-contouring time for the plates in both groups, was recorded.

resultsThe mean time of pre-contouring for the curved reconstruction plates in Group 2 was significantly less than in Group 1 (-55 min; P < 0.01). The mean time of 3D printing for the 3D plate template model in Group 2 was significantly less than that for the 3D pelvic model in Group 1 (-869 min; P < 0.01). Experimental results showed that the printing time for the plate pre-contouring and the 3D plate templates could be effectively reduced by approximately 93% and 90%, respectively.

conclusionThis method can shorten the preoperative preparation time significantly.

Indexed as

Fractures, BonePelvic BonesBone PlatesFracture Fixation, InternalHumansPreoperative CarePrinting, Three-DimensionalTomography, X-Ray ComputedAnterior pelvic ring fracture surgeryComputed tomography (CT)-based 3D medical imagingCurved reconstruction platesPreoperative surgical planningThree-dimensional (3D) printing

Identifiers

PMID37005637
PMCPMC10067232
OpenAlexW4362523749

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.