Evidence map›Paper›PMID 37004392›Full record

ArticleJournal of biomechanics2023

The effect of hip exoskeleton weight on kinematics, kinetics, and electromyography during human walking.

Michael A Normand, Jeonghwan Lee, Hao Su, James S Sulzer

Registry-linked trialOpen access · greenAbstract read
In one paragraph

Article in Journal of biomechanics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05120115 (Evaluating Optimal Weight Design Parameters of a Hip Exoskeleton Designed for Rehabilitation.), which is not on this map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
1.4field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05120115 nacompletednot on this map

Evaluating Optimal Weight Design Parameters of a Hip Exoskeleton Designed for Rehabilitation.

TypeinterventionalSponsorUniversity of Texas at AustinRan2021 to 2022Enrolled21ConditionsHealthy, Gait, FrontalArmsWeight belt
3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it, 13 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 1 country.

Michael A NormandMechanical Engineering at the University of Texas at Austin, Austin, TX, USA.
Jeonghwan LeeMechanical Engineering at the University of Texas at Austin, Austin, TX, USA.
Hao SuDepartment of Mechanical and Aerospace Engineering, North Carolina State University and Joint NCSU/UNC Department of Biomedical Engineering, North Carolina State University, Raleigh, NC, 27695, USA; University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA.
James S SulzerDepartment of Physical Medicine and Rehabilitation at MetroHealth Hospital and Case Western Reserve University, Cleveland, OH, USA. Electronic address: jss280@case.edu.
The University of Texas at Austin · USMetro Health Hospital · USUniversity of North Carolina at Chapel Hill · US

Funding

Combining neurophysiology and biomechanics to delineate post-stroke gait impairmentsR01HD100416 · NICHD · UNIVERSITY OF TEXAS AT AUSTIN · PI SULZER, JAMES · 2020 to 2024
$2.0M
NICHD NIH HHS R01 HD100416
6 · The paper itself

Abstract

In exoskeleton research, transparency is the degree to which a device hinders the movement of the user, a critical component of performance and usability. Transparency is most often evaluated individually, thus lacking generalization. Our goal was to systematically evaluate transparency due to inertial effects on gait of a hypothetical hip exoskeleton. We predicted that the weight distribution around the pelvis and the amount of weight applied would change gait characteristics. We instructed 21 healthy individuals to walk on a treadmill while bearing weights on the pelvis between 4 and 8 kg in three different configurations, bilaterally, unilaterally (left side) and on the lumbar portion of the back (L4). We measured kinematics, kinetics, and muscle activity during randomly ordered trials of 1.5 min at typical walking speed. We also calculated the margin of stability to measure medial-lateral stability. We observed that loading the hips bilaterally with 4 kg had no changes in kinematics, kinetics, dynamic stability, or muscle activity, but above 6 kg, sagittal joint power was increased. Loading the lumbar area increased posterior pelvic tilt at 6 kg and decreased dynamic stability at 4 kg, with many individuals reporting some discomfort. For the unilateral placement, above 4 kg dynamic stability was decreased and hip joint power was increased, and above 6 kg the pelvis begins to dip towards the loaded side. These results show the different effects of weight distribution around the pelvis. This study represents a novel, systematic approach to characterizing transparency in exoskeleton design (clinicaltrials.gov: NCT05120115).

Indexed as

Exoskeleton DeviceBiomechanical PhenomenaElectromyographyGaitHumansWalkingExoskeletonGaitLoadingWeight

Identifiers

PMID37004392
PMCPMC11003446
OpenAlexW4362474960

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials