Validity and intrarater reliability of a novel device for assessing Plantar flexor strength.

Seth O'Neill, Alice Weeks, Jens Eg Nørgaard, Martin Gronbech Jorgensen

2 registry-linked trialsOpen access · goldAbstract read
In one paragraph

Article in PloS one, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
2.9field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05888688 recruitingnot on this map

The Imaging Assessment of Sarcopenia Across the Heart Failure Spectrum

Typeobservational_patient_registrySponsorUniversity of LeicesterRan2023 to 2026Enrolled80ConditionsHeart Failure, Sarcopenia, Heart Failure With Reduced Ejection Fraction, Heart Failure With Preserved Ejection Fraction
NCT07498166 naactive not recruitingnot on this mapstarted 2026, after this paper: background citation

Project Tendura: The Impact of Blood Flow Restriction Resistance Training (BFR-RT) in Patients With Achilles Tendon Rupture (ATR) Repair

TypeinterventionalSponsorMassachusetts General HospitalRan2026 to 2027Enrolled75ConditionsAchilles Tendon Rupture, Blood Flow Restriction Therapy, Achilles Tendon Repairs/Reconstructions, Dynamic Blood Flow RestrictionArmsBlood Flow Restriction Resistance Training (BFR-RT), Sham Blood Flow Restriction, Standard Physical Therapy
3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 2 countries.

Seth O'NeillSchool of Healthcare, College of Life sciences, University of Leicester, Leicester, United Kingdom.ORCID 0000-0002-0904-1381
Alice WeeksSchool of Healthcare, College of Life sciences, University of Leicester, Leicester, United Kingdom.
Jens Eg NørgaardDepartment of Geriatric Medicine, Aalborg University Hospital, Aalborg, Denmark.ORCID 0000-0002-5256-6108
Martin Gronbech JorgensenDepartment of Geriatric Medicine, Aalborg University Hospital, Aalborg, Denmark.
Aalborg University Hospital · DKUniversity of Leicester · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionPlantar flexor weakness is an identified prospective factor for developing Achilles tendinopathy. Various authors have reported relationships between symptoms and weakness of this muscle group. Despite this relationship, many clinicians and researchers fail to examine Plantar flexor strength due to the cumbersome, stationary and expensive nature of an isokinetic dynamometer (IKD), known as the "Gold Standard". This study examined the validity and reliability of a fast, easy and portable device for assessing plantarflexion.

methodsValidity between the Cybex NORM® by Humac and the C-Station by Fysiometer was explored using Pearson correlation coefficient. Participants were randomly selected to start in the Cybex NORM® or the FysioMeter C-Station. Intra-rater reliability on the C-station was investigated by test-retest two days apart using Intraclass Correlation Coefficient (ICC). All testing involved isometric maximal force of the soleus muscle with the knee at 90 degrees flexion.

results40 healthy university students were recruited for the validity part, while 65 healthy university students were recruited for the reliability part of the study. The mean peak torque on the IKD was 198.55Nm (SD 94.45) versus 1443.88 (412.82)N on the C-Station. The results of the Pearson correlation revealed an r-value of r = 0.72 with a 95%CI 0.52-0.84. The test re-test reliability was calculated as an ICC of 0.91 with a (95%CI 0.86-0.94).

conclusionsThe C-Station by Fysiometer appears to provide valid measures and have excellent reliability for Plantar flexor isometric strength. It would appear suitable for both clinical and research work.

Indexed as

Achilles TendonTendinopathyHumansIsometric ContractionMuscle, SkeletalMuscle StrengthMuscle Strength DynamometerProspective StudiesReproducibility of Results

Identifiers

PMID37000780
PMCPMC10065227
OpenAlexW4362473776

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.