Evidence map›Paper›PMID 37000268›Full record

Trial reportArchives of orthopaedic and trauma surgery2023

Curve-on-curve technique does not improve tibial coverage in total knee arthroplasty in comparison to tibial tuberosity technique with use of anatomical implants: randomized controlled trial.

Bartosz M Maciąg, Tomasz Kordyaczny, Krystian Żarnovsky, Martyna Budzińska, Dawid Jegierski, Marcin Łapiński, Grzegorz J Maciąg, Artur Stolarczyk

Open access · hybridAbstract readRandomized Controlled Trial
In one paragraph

Trial report in Archives of orthopaedic and trauma surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed, 1 pooled it
0.3field-weighted citation impact, top 43% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 synthesis or guideline pooled it, 1 citations in OpenAlex.

  1. Pooled it
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Bartosz M MaciągDepartment of Orthopedics and Rehabilitation, Medical University of Warsaw, Międzyleski Specialist Hospital, 2 Bursztynowa St., 04-749, Warsaw, Poland. bmaciag@wum.edu.pl.ORCID http://orcid.org/0000-0002-0311-3735
Tomasz KordyacznyDepartment of Orthopedics and Rehabilitation, Medical University of Warsaw, Międzyleski Specialist Hospital, 2 Bursztynowa St., 04-749, Warsaw, Poland.
Krystian ŻarnovskyDepartment of Orthopedics and Rehabilitation, Medical University of Warsaw, Międzyleski Specialist Hospital, 2 Bursztynowa St., 04-749, Warsaw, Poland.
Martyna BudzińskaDepartment of Orthopedics and Rehabilitation, Medical University of Warsaw, Międzyleski Specialist Hospital, 2 Bursztynowa St., 04-749, Warsaw, Poland.
Dawid JegierskiDepartment of Orthopedics and Rehabilitation, Medical University of Warsaw, Międzyleski Specialist Hospital, 2 Bursztynowa St., 04-749, Warsaw, Poland.
Marcin ŁapińskiDepartment of Orthopedics and Rehabilitation, Medical University of Warsaw, Międzyleski Specialist Hospital, 2 Bursztynowa St., 04-749, Warsaw, Poland.
Grzegorz J MaciągDepartment of Orthopedics and Rehabilitation, Medical University of Warsaw, Międzyleski Specialist Hospital, 2 Bursztynowa St., 04-749, Warsaw, Poland.
Artur StolarczykDepartment of Orthopedics and Rehabilitation, Medical University of Warsaw, Międzyleski Specialist Hospital, 2 Bursztynowa St., 04-749, Warsaw, Poland.
Medical University of Warsaw · PL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionDuring the last years, main attention while performing total knee replacement was paid to femoral component alignment; however, there is still lack of studies concerning tibial baseplate rotational alignment, especially in terms of anatomical designs of knee prosthesis. Some recent studies proved that tibial baseplate malrotation might be a cause of knee pain and patients' dissatisfaction. The aim of this study was to compare tibial component rotation and its coverage on the tibial plateau achieved with curve-on-curve and tibial tuberosity techniques (t-t technique) with use of anatomic knee designs with asymmetric tibial baseplate. MATERIALS AND

methodsA total of 88 patients were randomly assigned in a 1:1 ratio to undergo total knee arthroplasty with use of the PERSONA PS (Zimmer Biomet) knee design with an asymmetric baseplate. The rotation of the tibial component was assessed and performed with two different techniques: curve-on-curve technique and tibial tuberosity technique. Tibial component rotation was measured on computed tomography (CT) scans using the method suggested by Benazzo et al. and designed for asymmetrical implants. For the measurement of the tibial bone coverage, the component surface area was outlined and measured on a proper CT section, then the tibial cut surface area was outlined and measured on a section just below the cement level. Pre- and post-operative range of motion was measured by another independent researcher 12 months post-operatively during follow-up visit.

resultsThere was a statistically significant difference between both groups in median value of tibial rotation angle: 7° (interquartile range (IQR) = 0-12) in curve-on-curve technique group vs 2° (IQR-1-7) in tibial tuberosity technique group, probability value (p) = 0.0041, with values above 0 meaning external rotation of the component. There was no statistically significant difference between both groups in terms of range of motion (ROM) with average values of 124.3° ± 13.0° for curve-on-curve technique and 125.6° ± 12.8° for t-t technique with p = 0.45. There was a statistically insignificant difference between both groups in terms of coverage percentage in slight favor for curve-on-curve technique (85.9 ± 4.2 vs 84.5 ± 4.8, p = 0.17).

conclusionIn this study, no difference between the groups in terms of tibial bone coverage and range of motion was proved, even though both techniques differed significantly with values of tibial rotation. Future studies should be focused on influence of specific values of tibial rotation on patient-reported outcomes and survivorship of anatomic knee implants.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisHumansKnee JointTibiaTomography, X-Ray ComputedAnatomic designCoverageTibial rotationTotal knee arthroplasty

Identifiers

PMID37000268
PMCPMC10064952
OpenAlexW4362522165

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.