ArticleJournal of applied clinical medical physics2023
Artifact removal for unpaired thorax CBCT images using a feature fusion residual network and contextual loss.
Article in Journal of applied clinical medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Artifact removal for unpaired thorax CBCT images using a feature fusion residual network and contextual loss.Journal of applied clinical medical physics · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
BACKGROUND AND
objectiveCone-beam computed tomography (CBCT) has become a more and more active cutting-edge topic in the international computed tomography (CT) research due to its advantages of fast scanning speed, high ray utilization rate and high precision. However, scatter artifacts affect the imaging performance of CBCT, which hinders its application seriously. Therefore, our study aimed to propose a novel algorithm for scatter artifacts suppression in thorax CBCT based on a feature fusion residual network (FFRN), where the contextual loss was introduced to adapt the unpaired datasets better.
methodsIn the method we proposed, a FFRN with contextual loss was used to reduce CBCT artifacts in the region of chest. Unlike L1 or L2 loss, the contextual loss function makes input images which are not aligned strictly in space available, so we performed it on our unpaired datasets. The algorithm aims to reduce artifacts via studying the mapping between CBCT and CT images, where the CBCT images were set as the beginning while planning CT images as the end.
resultsThe proposed method effectively removes artifacts in thorax CBCT, including shadow artifacts and cup artifacts which can be collectively referred to as uneven grayscale artifacts, in the CBCT image, and perform well in preserving details and maintaining the original shape. In addition, the average PSNR number of our proposed method achieved 27.7, which was higher than the methods this paper referred which indicated the significance of our method.
conclusionsWhat is revealed by the results is that our method provides a highly effective, rapid, and robust solution for the removal of scatter artifacts in thorax CBCT images. Moreover, as is shown in Table 1, our method has demonstrated better artifact reduction capability than other methods.