ArticleBMC musculoskeletal disorders2023
Influence of preoperative simulation on the reduction quality and clinical outcomes of open reduction and internal fixation for complex proximal humerus fractures.
Article in BMC musculoskeletal disorders, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed.
- A Comprehensive Review of 3D Imaging and Printing in Proximal Humerus Fractures and Sequelae.Journal of clinical medicine · 2025Review
- [Analysis of anatomical characteristics of proximal humerus measured based on three-dimensional reconstruction technique and its clinical significance].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2025Article
- Shape-matching-based fracture reduction aid concept exemplified on the proximal humerus-a pilot study.International journal of computer assisted radiology and surgery · 2025Article
- Clinical validation of artificial intelligence-based preoperative virtual reduction for Neer 3- or 4-part proximal humerus fractures.BMC musculoskeletal disorders · 2024Article
- Analysis of the associated factors in postoperative wound infection following open reduction and internal fixation for elbow fracture.International wound journal · 2024Article
- 3D printing assisted MIPO for treatment of complex middle-proximal humeral shaft fractures.BMC musculoskeletal disorders · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeProximal humerus fractures (PHFs) are common. With the development of locking plates, open reduction and internal fixation (ORIF) of the proximal humerus can provide excellent clinical outcomes. The quality of fracture reduction is crucial in the locking plate fixation of proximal humeral fractures. The purpose of this study was to determine the impact of 3-dimensional (3D) printing technology and computer virtual technology assisted preoperative simulation on the reduction quality and clinical outcomes of 3-part and 4-part proximal humeral fractures.
methodA retrospective comparative analysis of 3-part and 4-part PHFs undergoing open reduction internal fixation was performed. Patients were divided into 2 groups according to whether computer virtual technology and 3D printed technology were used for preoperative simulation: the simulation group and the conventional group. Operative time, intraoperative bleeding, hospital stay, quality of fracture reduction, Constant scores, American Society for Shoulder and Elbow Surgery (ASES) scores, shoulder range of motion, complications, and revision surgeries were assessed.
resultsThis study included 67 patients (58.3%) in the conventional group and 48 patients (41.7%) in the simulation group. The patient demographics and fracture characteristics were comparable in these groups. Compared with the conventional group, the simulation group had shorter operation time and less intraoperative bleeding (P < 0.001, both). Immediate postoperative assessment of fracture reduction showed a higher incidence of greater tuberosity cranialization of < 5 mm, neck-shaft angle of 120° to 150°, and head shaft displacement of < 5 mm in the simulation group. The incidence of good reduction was 2.6 times higher in the simulation group than in the conventional group (95% CI, 1.2-5.8). At the final follow-up, the chance of forward flexion > 120° (OR 5.8, 95% CI 1.8-18.0) and mean constant score of > 65 (OR 3.4, 95% CI 1.5-7.4) was higher in the simulation group than the conventional group, as well as a lower incidence of complications in the simulation group was obtained (OR 0.2, 95% CI 0.1-0.6).
conclusionsThis study identified that preoperative simulation assisted by computer virtual technology and 3D printed technology can improve reduction quality and clinical outcomes in treatment of 3-part and 4-part PHFs.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.