ArticleBMC ophthalmology2023
Transscleral vs endoscopic cyclophotocoagulation: safety and efficacy when combined with phacoemulsification.
Article in BMC ophthalmology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 8 citations in OpenAlex.
- Analysis of Pediatric Secondary Glaucoma Patients Treated with Micropulse Transscleral Cyclophotocoagulation (MP-TSCPC).Life (Basel, Switzerland) · 2026Article
- Complications following incisional glaucoma surgery, minimally invasive glaucoma surgery, and cycloablative procedures: a 13-year retrospective review.Digital journal of ophthalmology : DJO · 2026Article
- Comparison Between Phacoemulsification-iStent Inject W and Phacoemulsification-Micropulse Transscleral Laser Therapy in Asian Eyes With Mild-Moderate Open Angle Glaucoma.Journal of glaucoma · 2025Article
- Case report: a two-step approach in the management of angle-closure glaucoma associated with Plateau iris configuration.Arquivos brasileiros de oftalmologia · 2025Article
- Review
- Comparing Outcomes of Phacoemulsification and Endocyclophotocoagulation with Either Dual Blade Goniotomy (PEcK) or Two Trabecular Stents (ICE2).Clinical ophthalmology (Auckland, N.Z.) · 2023Article
- Comparative Study: Phaco with Micropulse Cyclophotocoagulation vs Phaco with Endoscopic Cyclophotocoagulation.Journal of current glaucoma practiceArticle
- Endoscopic cyclophotocoagulation for glaucoma compared to alternative procedures -A Systematic review.Oman journal of ophthalmologyReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeTo compare the effectiveness and safety of phacoemulsification combined with endoscopic cyclophotocoagulation (phaco/ECP), phacoemulsification combined with MicroPulse transscleral cyclophotocoagulation (phaco/MP-TSCPC), and phacoemulsification alone (phaco) in the treatment of coexisting cataract and glaucoma.
methodsRetrospective cohort study of consecutive cases at Massachusetts Eye & Ear. The main outcome measures were the cumulative probabilities of failure between the phaco/ECP group, phaco/MP-TSCPC group, and the phaco alone group with failure defined as reaching NLP vision at any point postoperatively, undergoing additional glaucoma surgery, or the inability to maintain ≥ 20% IOP reduction from baseline with IOP between 5-18 mmHg while maintaining ≤ baseline medications. Additional outcome measures included changes in average IOP, number of glaucoma medications, and complication rates.
resultsSixty-four eyes from 64 patients (25 phaco/ECP, 20 phaco/MPTSCPC, 19 phaco alone) were included in this study. The groups did not differ in age (mean 71.04 ± 6.7 years) or length of follow-up time. Baseline IOPs were significantly different between groups (15.78 ± 4.7 mmHg phaco/ECP, 18.37 ± 4.6 mmHg phaco/MP-TSCPC, 14.30 ± 4.2 mmHg phaco alone, p = 0.02). Primary open-angle glaucoma was the most common type of glaucoma in the phaco alone (42%) and phaco/ECP (48%) groups while mixed-mechanism glaucoma was the most common type in the phaco/MP-TSCPC group (40%). Surgical failure was less likely in eyes in the phaco/MP-TSCPC (3.40 times, p = 0.005) and phaco/ECP (1.40 times, p = 0.044) groups compared to phaco alone based on the Kaplan-Meier survival criteria. These differences maintained statistical significance when differences in preoperative IOP were taken into account using the Cox PH model (p = 0.011 and p = 0.004, respectively). Additionally, surgical failure was 1.98 times less likely following phaco/MP-TSCPC compared to phaco/ECP (p = 0.038). This difference only approached significance once differences in preoperative IOP were accounted for (p = 0.052). There was no significant difference in IOP reduction at 1 year between groups. Mean IOP reductions at 1 year were 3.07 ± 5.3 mmHg from a baseline of 15.78 ± 4.7 in the phaco/ECP group, 6.0 ± 4.3 mmHg from a baseline of 18.37 ± 4.6 in the phaco/MP-TSCPC group and 1.0 ± 1.6 from a baseline of 14.30 ± 4.2 mmHg in the phaco alone group. There were no differences in complication rates among the three groups.
conclusionsBoth Phaco/MP-TSCPC and phaco/ECP appear to provide superior efficacy for IOP control when compared to phaco alone. All three procedures had similar safety profiles.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.