Evidence map›Paper›PMID 36997829›Full record

ArticleInternational journal of computer assisted radiology and surgery2023

MRI-based training model for left atrial appendage closure.

Dagmar Bertsche, Mona Pfisterer, Tillman Dahme, Leonhard-Moritz Schneider, Patrick Metze, Ina Vernikouskaya, Volker Rasche

Abstract read
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. A Comprehensive Review of Percutaneous and Surgical Left Atrial Appendage Occlusion.Journal of cardiovascular development and disease · 2024
    Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Dagmar BertscheDepartment of Internal Medicine II, Ulm University Medical Center, Ulm, Germany.ORCID http://orcid.org/0000-0003-1020-6718
Mona PfistererDepartment of Internal Medicine II, Ulm University Medical Center, Ulm, Germany.
Tillman DahmeDepartment of Internal Medicine II, Ulm University Medical Center, Ulm, Germany.
Leonhard-Moritz SchneiderDepartment of Internal Medicine II, Ulm University Medical Center, Ulm, Germany.
Patrick MetzeDepartment of Internal Medicine II, Ulm University Medical Center, Ulm, Germany.
Ina VernikouskayaDepartment of Internal Medicine II, Ulm University Medical Center, Ulm, Germany.ORCID http://orcid.org/0000-0002-4187-5685
Volker RascheDepartment of Internal Medicine II, Ulm University Medical Center, Ulm, Germany. volker.rasche@uni-ulm.de.ORCID http://orcid.org/0000-0001-8844-3583

Funding

Bundesministerium für Bildung und Forschung 13GW0372C
6 · The paper itself

Abstract

purposePercutaneous closure of the left atrial appendage (LAA) reduces the risk of embolic stroke in patients with atrial fibrillation. Thereby, the optimal transseptal puncture (TSP) site differs due to the highly variable anatomical shape of the LAA, which is rarely considered in existing training models. Based on non-contrast-enhanced magnetic resonance imaging (MRI) volumes, we propose a training model for LAA closure with interchangeable and patient-specific LAA enabling LAA-specific identification of the TSP site best suited.

methodsBased on patient-specific MRI data, silicone models of the LAAs were produced using a 3D-printed cast model. In addition, an MRI-derived 3D-printed base model was set up, including the right and left atrium with predefined passages in the septum, mimicking multiple TSP sites. The various silicone models and a tube mimicking venous access were connected to the base model. Empirical use of the model allowed the demonstration of its usability.

resultsPatient-specific silicone models of the LAA could be generated from all LAA patient MRI datasets. The influence of various combinations regarding TSP sites and LAA shapes could be demonstrated as well as the technical functionality of the occluder system. Via the attached tube mimicking the venous access, the correct handling of the deployment catheter even in case of not optimal puncture site could be practiced.

conclusionThe proposed contrast-agent and radiation-free MRI-based training model for percutaneous LAA closure enables the pre-interventional assessment of the influence of the TSP site on the access of patient-specific LAA shapes. A straightforward replication of this work is measured by using clinically available imaging protocols and a widespread 3D printer technique to build the model.

Indexed as

Atrial AppendageAtrial FibrillationMagnetic Resonance ImagingPrinting, Three-DimensionalCardiac Surgical ProceduresHumansLeft Atrial Appendage ClosureModels, AnatomicPuncturesLAA closureTraining modelTransseptal puncture

Identifiers

PMID36997829
PMCPMC10589139

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.