Evidence map›Paper›PMID 36997725›Full record

ArticleChild's nervous system : ChNS : official journal of the International Society for Pediatric Neurosurgery2023

Validation of a shortened MR imaging protocol for pediatric spinal pathology.

W Wu, E Miller, J Hurteau-Miller, M Thipse, C Kapoor, R Webster, D McAuley, A Tu

Abstract read
PubMed Publisher
In one paragraph

Article in Child's nervous system : ChNS : official journal of the International Society for Pediatric Neurosurgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

W WuFaculty of Medicine, University of Ottawa, Ottawa, Canada.
E MillerDepartment of Medical Imaging, University of Ottawa, CHEO, 401 Smyth Ave, Ottawa, ON, K1H8L1, Canada.
J Hurteau-MillerDepartment of Medical Imaging, University of Ottawa, CHEO, 401 Smyth Ave, Ottawa, ON, K1H8L1, Canada.
M ThipseCHEO Research Institute, 401 Smyth Ave, Ottawa, ON, K1H8L1, Canada.
C KapoorDepartment of Medical Imaging, University of Ottawa, CHEO, 401 Smyth Ave, Ottawa, ON, K1H8L1, Canada.
R WebsterCHEO Research Institute, 401 Smyth Ave, Ottawa, ON, K1H8L1, Canada.
D McAuleyDivision of Pediatric Neurosurgery, Department of Surgery, Rm 3359, CHEO, 401 Smyth Ave, Ottawa, ON, K1H8L1, Canada.
A TuDivision of Pediatric Neurosurgery, Department of Surgery, Rm 3359, CHEO, 401 Smyth Ave, Ottawa, ON, K1H8L1, Canada. albert.d.tu@gmail.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveConventional pediatric spine MRI protocols have multiple sequences resulting in long acquisition times. Sedation is consequently required. This study evaluates the diagnostic capability of a limited MRI spine protocol for selected common pediatric indications.

methodsSpine MRIs at CHEO between 2017 and 2020 were reviewed across pediatric patients younger than four years old. Two blinded neuroradiologists reviewed limited scan sequences, and results were independently compared to previously reported findings from the complete imaging series. T2 sagittal sequences from the craniocervical junction to sacrum and T1 axial sequence of the lumbar spine constitute the short protocol, with the outcomes of interest being cerebellar ectopia, syrinx, level of conus, filum < 2 mm, fatty filum, and spinal dysraphism.

resultsA total of 105 studies were evaluated in 54 male and 51 female patients (mean age 19.2 months). The average combined scan time of the limited sequences was 15 min compared to 35 min for conventional protocols (delta = 20 min). The average percent agreement between full and limited sequences was > 95% in all but identifying a filum < 2 mm, where the percent agreement was 87%. Using limited MR sequences had high sensitivity (> 0.91) and specificity (> 0.99) for the detection of cerebellar ectopia, syrinx, fatty filum, and spinal dysraphism.

conclusionThis study demonstrates that selected spinal imaging sequences allow for consistent and accurate diagnosis of specific clinical conditions. A limited spine imaging protocol has potential as a screening test to reduce the need for full-sequence MRI scans. Further work is needed to determine utility of selected imaging for other clinical indications.

Indexed as

Neural Tube DefectsSpinal DysraphismSyringomyeliaChildChild, PreschoolFemaleHumansInfantLumbar VertebraeLumbosacral RegionMagnetic Resonance ImagingMaleRetrospective StudiesFast imagingGeneral anesthesiaImagingMRIPediatricsQuality improvementSpine

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.