Evidence map›Paper›PMID 36995539›Full record

ArticleJournal of experimental orthopaedics2023

Evaluation of the inter and intraobserver reproducibility of the "defect coverage index method", a new computed tomography assessment method of sagittal graft positioning in arthroscopic bone block procedures.

Cristina Delgado, Ignacio De Rus, Pablo Cañete, Jorge Díaz, Raquel Ruiz, Miguel García Navlet, Miguel Ángel Ruiz Ibán

Open access · goldAbstract read
In one paragraph

Article in Journal of experimental orthopaedics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.6field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 5 institutions in 1 country.

Cristina DelgadoHospital Universitario Fundación Jiménez Díaz, Madrid, Spain.ORCID http://orcid.org/0000-0003-2166-8264
Ignacio De RusHospital Universitario Torrejón, Madrid, Spain.
Pablo CañeteHospital Manises, Valencia, Spain.
Jorge DíazShoulder and Elbow Reconstructive Surgery Unit. Department of Orthopaedic Surgery and Traumatology, Hospital Universitario Ramón y Cajal, Cta Colmenar km 9,100, 28046, Madrid, Spain.
Raquel RuizShoulder and Elbow Reconstructive Surgery Unit. Department of Orthopaedic Surgery and Traumatology, Hospital Universitario Ramón y Cajal, Cta Colmenar km 9,100, 28046, Madrid, Spain.
Miguel García NavletHospital Asepeyo Coslada, Madrid, Spain.
Miguel Ángel Ruiz IbánShoulder and Elbow Reconstructive Surgery Unit. Department of Orthopaedic Surgery and Traumatology, Hospital Universitario Ramón y Cajal, Cta Colmenar km 9,100, 28046, Madrid, Spain. drmri@hotmail.com.
Hospital Universitario Ramón y Cajal · ESAsepeyo Hospital Sant Cugat · ESHospital de Manises · ESHospital Universitario de Torrejón · ESHospital Universitario Fundación Jiménez Díaz · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo assess the reproducibility of a new 2-dimensional computed tomography (CT) method of assessing graft positioning in arthroscopic bone block procedure.

methodsThis is a prospective observational study. Twenty-seven patients, (all men, mean [Standard deviation] age at surgery 30.9 [8.49] years) were included. Vertical graft position was assessed on the sagittal view by measuring the amount of glenoid bone defect covered by the graft. The length of the bone defect and the amount of graft covering the defect were measured. Positioning of the graft on the sagittal plane was classified as accurate if the graft covered at least 90% of the defect. Intraobserver and interobserver reproducibility was analyzed using intraclass correlation coefficients (ICC) and Kappa coefficient with 95% confidence.

resultsExcellent intraobserver reproducibility was found, with an ICC of 0.94 (CI 95%, 0.86-0.97). Interobserver reproducibility was good, with the ICC value of 0.71, ranging from 0.45 to 0.86 (CI 95%).

conclusionThis new method of assessing graft positioning in arthroscopic bone block procedures on 2-dimensional computed tomography scans is reliable, with an excellent intraobserver and good interobserver reproducibility. LEVEL OF EVIDENCE: III.

Indexed as

Bone block procedureComputed tomographyGlenoid bone defectReproducibilitySagittal positionShoulder instability

Identifiers

PMID36995539
PMCPMC10063754
OpenAlexW4361275526

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.