Evidence map›Paper›PMID 36995538›Full record

ArticleJournal of experimental orthopaedics2023

A biomechanical comparison between robotic and conventional total knee arthroplasty (TKA) in resection accuracy: a meta-analysis on cadaveric specimens.

Sean B Sequeira, Grant T Duvall, Henry Boucher

Open access · goldAbstract read
In one paragraph

Article in Journal of experimental orthopaedics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
2.5field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 8 citations in OpenAlex.

  1. Trial
  2. Article
  3. Reproducibility of a new device for robotic-assisted TKA surgery.Journal of experimental orthopaedics · 2025
    Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Sean B SequeiraDepartment of Orthopaedic Surgery, MedStar Union Memorial Hospital, 3333 North Calvert, Street, Suite 400, Baltimore, MD, 21218, USA. sean.sequeira@medstar.net.ORCID http://orcid.org/0000-0003-2564-8703
Grant T DuvallDepartment of Orthopaedic Surgery, MedStar Union Memorial Hospital, 3333 North Calvert, Street, Suite 400, Baltimore, MD, 21218, USA.
Henry BoucherDepartment of Orthopaedic Surgery, MedStar Union Memorial Hospital, 3333 North Calvert, Street, Suite 400, Baltimore, MD, 21218, USA.
MedStar Union Memorial Hospital · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeRobotic total knee arthroplasty (TKA) has seen a rapid increase in utilization with recent literature suggesting that implant accuracy and resection are better optimized than in conventional TKA. The purpose of this study was to evaluate the biomechanical properties of robotic-assisted versus conventional TKA in minimizing biplanar femoral and tibial resection error in cadaveric specimens.

methodsA systematic review and meta-analysis was performed by searching through PubMed, Cochrane library, and Embase to identify studies that analyzed the biomechanical properties of robotic assisted and conventional TKA, according to standard PRISMA guidelines. Evaluated outcomes included femoral coronal resection error (deg), femoral sagittal resection error (deg), tibial coronal resection error (deg), and tibial sagittal resection error (deg).

resultsSeven studies met inclusion criteria, including a total of 140 cadaveric specimens (robotic: 70, conventional: 70), for resection accuracy between robotic and conventional TKA. Pooled analysis from seven studies revealed a significant difference in femoral coronal and sagittal resection error in favor of robotic systems compared to conventional systems (p < 0.001 & p < 0.001, respectively). The pooled analysis from seven studies revealed a significant difference in tibial sagittal resection error in favor of robotic systems compared to conventional systems following TKA (p = 0.012). Posthoc power analysis revealed a power of 87.2%.

conclusionThe use of robotic TKA is associated with lower femoral coronal, lower femoral sagittal and tibial sagittal resection error compared to conventional TKA. It should be noted that these findings are purely biomechanical - surgeons should interpret these findings along with clinical differences between conventional and robotic systems to determine which system is best for each patient.

Indexed as

BiomechanicsCadavericCoronalResection errorSagittalTotal knee arthroplasty

Identifiers

PMID36995538
PMCPMC10063757
OpenAlexW4361280326

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.