Evidence map›Paper›PMID 36995513›Full record

ArticleInternational journal of computer assisted radiology and surgery2023

Robotically controlled three-dimensional micro-ultrasound for prostate biopsy guidance.

Reid Vassallo, Tajwar Abrar Aleef, Qi Zeng, Brian Wodlinger, Peter C Black, Septimiu E Salcudean

Abstract read
PubMed Publisher
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.8field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 7 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

Reid VassalloSchool of Biomedical Engineering, The University of British Columbia, 251-2222 Health Sciences Mall, Vancouver, BC, V6T 1Z3, Canada. reidvass@student.ubc.ca.
Tajwar Abrar AleefSchool of Biomedical Engineering, The University of British Columbia, 251-2222 Health Sciences Mall, Vancouver, BC, V6T 1Z3, Canada.
Qi ZengDepartment of Electrical and Computer Engineering, The University of British Columbia, 5500-2332 Main Mall, Vancouver, BC, V6T 1Z4, Canada.
Brian WodlingerExact Imaging, 15-7676 Woodbine Avenue, Markham, ON, L3R 2N2, Canada.
Peter C BlackDepartment of Urologic Sciences, The University of British Columbia, 2775 Laurel Street, Vancouver, BC, V5Z 1M9, Canada.
Septimiu E SalcudeanSchool of Biomedical Engineering, The University of British Columbia, 251-2222 Health Sciences Mall, Vancouver, BC, V6T 1Z3, Canada.
University of British Columbia · CAWoodward (United States) · US

Funding

Natural Sciences and Engineering Research Council of Canada CGS-DUniversity of British Columbia C.A. Lazlo Chair
6 · The paper itself

Abstract

purposeProstate imaging to guide biopsy remains unsatisfactory, with current solutions suffering from high complexity and poor accuracy and reliability. One novel entrant into this field is micro-ultrasound (microUS), which uses a high-frequency imaging probe to achieve very high spatial resolution, and achieves prostate cancer detection rates equivalent to multiparametric magnetic resonance imaging (mpMRI). However, the ExactVu transrectal microUS probe has a unique geometry that makes it challenging to acquire controlled, repeatable three-dimensional (3D) transrectal ultrasound (TRUS) volumes. We describe the design, fabrication, and validation of a 3D acquisition system that allows for the accurate use of the ExactVu microUS device for volumetric prostate imaging.

methodsThe design uses a motorized, computer-controlled brachytherapy stepper to rotate the ExactVu transducer about its axis. We perform geometric validation using a phantom with known dimensions and compare performance with magnetic resonance imaging (MRI) using a commercial quality assurance anthropomorphic prostate phantom.

resultsOur geometric validation shows accuracy of 1 mm or less in all three directions, and images of an anthropomorphic phantom qualitatively match those acquired using MRI and show good agreement quantitatively.

conclusionWe describe the first system to acquire robotically controlled 3D microUS images using the ExactVu microUS system. The reconstructed 3D microUS images are accurate, which will allow for future applications of the ExactVu microUS system in prostate specimen and in vivo imaging.

Indexed as

ProstateProstatic NeoplasmsHumansImage-Guided BiopsyImaging, Three-DimensionalMagnetic Resonance ImagingMaleReproducibility of ResultsUltrasonographyMicro-ultrasoundProstate cancerRoboticsThree dimensional

Identifiers

PMID36995513
OpenAlexW4361245493

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.