Evidence map›Paper›PMID 36995375›Full record

ArticleNeuroradiology2023

Optimization of workflow for detection of brain metastases at 3T: is a black-blood MTC prepared 3D T1 used alone robust enough to replace the combination of conventional 3D T1 and the black-blood 3D T1 MTC?

Sophia Chkili, Yolène Lefebvre, Shih-Li Chao, Maria Antonietta Bali, Marc Lemort, Nicolas Coquelet

Open access · hybridAbstract read
In one paragraph

Article in Neuroradiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.3field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Sophia ChkiliDepartment of Radiology, Institut Jules Bordet, 90 Rue Meylemeersch, 1070, Brussels, Belgium. sophia.chkili@hotmail.fr.ORCID http://orcid.org/0000-0002-4342-3455
Yolène LefebvreDepartment of Radiology, Institut Jules Bordet, 90 Rue Meylemeersch, 1070, Brussels, Belgium.
Shih-Li ChaoDepartment of Radiology, Institut Jules Bordet, 90 Rue Meylemeersch, 1070, Brussels, Belgium.
Maria Antonietta BaliDepartment of Radiology, Institut Jules Bordet, 90 Rue Meylemeersch, 1070, Brussels, Belgium.
Marc LemortDepartment of Radiology, Institut Jules Bordet, 90 Rue Meylemeersch, 1070, Brussels, Belgium.
Nicolas CoqueletDepartment of Radiology, Institut Jules Bordet, 90 Rue Meylemeersch, 1070, Brussels, Belgium.
Institut Jules Bordet · BE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeSampling perfection with application-optimized contrasts by using different flip angle evolutions (SPACE) is a black-blood 3D T1-weighted (T1w) magnetic resonance imaging (MRI) sequence that has shown robust performance for brain metastases detection. However, this could generate false positive results due to suboptimal blood signal suppression. For that reason, SPACE is used in our institution alongside a non-black-blood T1w sequence: volumetric interpolated breath-hold examination (VIBE). Our study aims to (i) evaluate the diagnostic accuracy of SPACE compared to its use in combination with VIBE, (ii) investigate the effect of radiologist's experience in the sequence's performance, and (iii) analyze causes of discordants results.

methodsFour hundred seventy-three 3T MRI scans were retrospectively analyzed following a monocentric study design. Two studies were formed: one including SPACE alone and one combining both sequences (SPACE + VIBE, the reference). An experienced neuroradiologist and a radiology trainee independently reviewed the images of each study and reported the number of brain metastases. The sensitivity (Se) and specificity (Sp) of SPACE compared to SPACE + VIBE in metastases detection were reported. Diagnostic accuracy of SPACE compared to SPACE + VIBE was assessed by using McNemar's test. Significance was set at p < 0.05. Cohen's kappa was used for inter-method and inter-observer variability.

resultsNo significant difference was found between the two methods, with SPACE having a Se > 93% and a Sp > 87%. No effect of readers' experience was disclosed.

conclusionIndependently of radiologist's experience, SPACE alone is robust enough to replace SPACE + VIBE for brain metastases detection.

Indexed as

Brain NeoplasmsImaging, Three-DimensionalContrast MediaHumansMagnetic Resonance ImagingRetrospective StudiesWorkflowContrast MediaBlack-bloodBrain metastasesContrast enhancementMagnetization transfer contrastT1-weighted sequenceVessel suppression

Identifiers

PMID36995375
PMCPMC10272253
OpenAlexW4361275753

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.