Evidence map›Paper›PMID 36994668›Full record

ArticleDiagnostic and interventional radiology (Ankara, Turkey)2024

Preoperative simulation results and intraoperative image fusion guidance for transjugular intrahepatic portosystemic shunt placement: a feasibility study of nineteen patients.

Xin Wei, Hong Hu, Lin Qi, Liming Zhong, Yunguo Liao, Jiaqi Pu

Abstract read
In one paragraph

Article in Diagnostic and interventional radiology (Ankara, Turkey), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Xin WeiNanchong Central Hospital, The Second Clinical College of North Sichuan Medical College, Department of Interventional Radiology, Nanchong, ChinaORCID 0000-0002-7360-5065
Hong HuNanchong Central Hospital, The Second Clinical College of North Sichuan Medical College, Department of Interventional Radiology, Nanchong, ChinaORCID 0000-0003-1961-8540
Lin QiNorth Sichuan Medical College, Nanchong, School of Medical Imaging, Nanchong, ChinaORCID 0000-0003-1438-5207
Liming ZhongNanchong Central Hospital, The Second Clinical College of North Sichuan Medical College, Department of Interventional Radiology, Nanchong, ChinaORCID 0000-0003-1829-4310
Yunguo LiaoNanchong Central Hospital, The Second Clinical College of North Sichuan Medical College, Department of Interventional Radiology, Nanchong, ChinaORCID 0000-0001-5821-4480
Jiaqi PuNanchong Central Hospital, The Second Clinical College of North Sichuan Medical College, Department of Interventional Radiology, Nanchong, ChinaORCID 0000-0002-2622-1974

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe purpose is to evaluate the feasibility and efficacy of preoperative simulation results and intraoperative image fusion guidance during transjugular intrahepatic portosystemic shunt (TIPS) creation.

methodsNineteen patients were enrolled in the present study. The three-dimensional (3D) structures of the bone, liver, portal vein, inferior vena cava, and hepatic vein in the contrast-enhanced computed tomography (CT) scanning area were reconstructed in the Mimics software. The virtual Rosch-Uchida liver access set and the VIATORR stent model were established in the 3D Max software. The puncture path from the hepatic vein to the portal vein and the release position of the stent were simulated in the Mimics and 3D Max software, respectively. The simulation results were exported to Photoshop software, and the 3D reconstructed top of the liver diaphragm was used as the registration point to fuse with the liver diaphragmatic surface of the intraoperative fluoroscopy image. The selected portal vein system fusion image was overlaid on the reference display screen to provide image guidance during the operation. As a control, the last 19 consecutive cases of portal vein puncture under the guidance of conventional fluoroscopy were analyzed retrospectively, including the number of puncture attempts, puncture time, total procedure time, total fluoroscopy time, and total exposure dose (dose area product).

resultsThe average time of preoperative simulation was about 61.26 ± 6.98 minutes. The average time of intraoperative image fusion was 6.05 ± 1.13 minutes. The median number of puncture attempts was not significantly different between the study group (n = 3) and the control group (n = 3;

conclusionThe use of preoperative simulation results and intraoperative image fusion to guide a portal vein puncture is feasible, safe, and effective when creating a TIPS. The method is cheap and may improve portal vein puncture, which may be valuable for hospitals lacking intravascular ultrasound and digital subtraction angiography (DSA) equipment equipped with a CT-angiography function.

Indexed as

Portasystemic Shunt, Transjugular IntrahepaticFeasibility StudiesHepatic VeinsHumansPortal VeinRetrospective StudiesTreatment OutcomeCirrhosisimage fusion guidanceportal hypertensionsimulationthree-dimensional reconstructiontransjugular intrahepatic portosystemic shunt

Identifiers

PMID36994668
PMCPMC10916528

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.