Evidence map›Paper›PMID 36992033›Full record

ArticleSensors (Basel, Switzerland)2023

Optoelectronic Pressure Sensor Based on the Bending Loss of Plastic Optical Fibers Embedded in Stretchable Polydimethylsiloxane.

Alberto Alonso Romero, Koffi Novignon Amouzou, Dipankar Sengupta, Camila Aparecida Zimmermann, Andréane Richard-Denis, Jean-Marc Mac-Thiong, Yvan Petit, Jean-Marc Lina, Bora Ung

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.9field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 17 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

Alberto Alonso RomeroElectrical Engineering Department, École de Technologie Supérieure, 1100 Notre-Dame Street West, Montreal, QC H3C 1K3, Canada.ORCID 0000-0003-2588-8977
Koffi Novignon AmouzouElectrical Engineering Department, École de Technologie Supérieure, 1100 Notre-Dame Street West, Montreal, QC H3C 1K3, Canada.ORCID 0000-0002-6584-6897
Dipankar SenguptaElectrical Engineering Department, École de Technologie Supérieure, 1100 Notre-Dame Street West, Montreal, QC H3C 1K3, Canada.
Camila Aparecida ZimmermannElectrical Engineering Department, École de Technologie Supérieure, 1100 Notre-Dame Street West, Montreal, QC H3C 1K3, Canada.ORCID 0000-0001-9573-0900
Andréane Richard-DenisHôpital du Sacré-Cœur de Montréal, 5400 Gouin Boul. West, Montreal, QC H4J 1C5, Canada.
Jean-Marc Mac-ThiongHôpital du Sacré-Cœur de Montréal, 5400 Gouin Boul. West, Montreal, QC H4J 1C5, Canada.
Yvan PetitMechanical Engineering Department, École de Technologie Supérieure, 1100 Notre-Dame Street West, Montreal, QC H3C 1K3, Canada.ORCID 0000-0003-1428-8191
Jean-Marc LinaElectrical Engineering Department, École de Technologie Supérieure, 1100 Notre-Dame Street West, Montreal, QC H3C 1K3, Canada.
Bora UngElectrical Engineering Department, École de Technologie Supérieure, 1100 Notre-Dame Street West, Montreal, QC H3C 1K3, Canada.ORCID 0000-0003-1046-9489
École de Technologie Supérieure · CAHôpital du Sacré-Cœur de Montréal · CA

Funding

New Frontiers in Research Fund NFRFE-2019-00822
6 · The paper itself

Abstract

We report the design and testing of a sensor pad based on optical and flexible materials for the development of pressure monitoring devices. This project aims to create a flexible and low-cost pressure sensor based on a two-dimensional grid of plastic optical fibers embedded in a pad of flexible and stretchable polydimethylsiloxane (PDMS). The opposite ends of each fiber are connected to an LED and a photodiode, respectively, to excite and measure light intensity changes due to the local bending of the pressure points on the PDMS pad. Tests were performed in order to study the sensitivity and repeatability of the designed flexible pressure sensor.

Indexed as

bendingcommercial electronic componentscost-effectiveflexible pressure sensorlight intensityplastic optical fiberpolydimethylsiloxanesimple fabrication

Identifiers

PMID36992033
PMCPMC10053520
OpenAlexW4353072703

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked