Evidence map›Paper›PMID 36991928›Full record

ArticleSensors (Basel, Switzerland)2023

Measurements of Small Frequency Differences by Dual Mode 4 MHz Quartz Sensors.

Vojko Matko

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Vojko MatkoFaculty of Electrical Engineering and Computer Science, University of Maribor, Koroška c. 46, 2000 Maribor, Slovenia.ORCID 0000-0002-0842-1374

Funding

Slovenian Research Agency P2-0028
6 · The paper itself

Abstract

We proposed a method for measuring frequency differences of the order of a few Hz with an experimental error lower than 0.0001% by using two 4 MHz quartz oscillators, the frequencies of which are very close (a few 10 Hz difference) due to the dual mode operation (differential mode with two temperature-compensated signal frequencies or a mode with one signal and one reference frequency). We compared the existing methods for measuring frequency differences with the new method which is based on counting the number of transitions through zero within one beat period of the signal. The measuring procedure requires equal experimental conditions (temperature, pressure, humidity, parasitic impedances etc.) for both quartz oscillators. To ensure equal resonant conditions for oscillation two quartz crystals are needed, which form a temperature pair. The frequencies and resonant conditions of both oscillators must be almost equal, which is achieved by an external inductance or capacitance. In such a way, we minimized all the external effects and ensured highly stable oscillations and high sensitivity of the differential sensors. The counter detects one beat period by an external gate signal former. By using the method of counting transitions through zero within one beat period, we reduced the measuring error by three orders of magnitude, compared to the existing methods.

Indexed as

differential sensorsquartz oscillatorssmall frequency difference measurementtemperature-compensated quartz sensorstransitions-through-zero method