ArticleSensors (Basel, Switzerland)2023
An Effective Method for Improving Low-Frequency Response of Geophone.
Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Design of Low-Frequency Extended Signal Conditioning Circuit for Coal Mine Geophone.Sensors (Basel, Switzerland) · 2025Article
- Frequency Response and Material Property Sensitivity Analysis of Moving-Coil Geophone Using Finite Element Simulation.Sensors (Basel, Switzerland) · 2025Article
- Development of a Sandwiched Piezoelectric Accelerometer for Low-Frequency and Wide-Band Seismic Exploration.Sensors (Basel, Switzerland) · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
The natural frequency of traditional velocity sensors such as moving coil geophones limits their measurable low-frequency range, and the damping ratio affects the flatness of the sensor in the amplitude and frequency curves, resulting in variations in sensitivity over the available frequency range. In this paper, the structure and working principle of the geophone are analyzed and its dynamics are modeled. After synthesizing the negative resistance method and zero-pole compensation, two commonly adopted low-frequency extension methods, a method for improving low-frequency response, which is a series filter and a subtraction circuit to increase the damping ratio, is proposed. Applying this method to improve the low-frequency response of the JF-20DX geophone, which has a natural frequency of 10 Hz, results in a flat response to acceleration in the frequency range from 1 to 100 Hz. Both the PSpice simulation and actual measurement show a much lower noise level via the new method. Testing the vibration at 10 Hz, the new method has a 17.52 dB higher signal-to-noise ratio than the traditional zero-pole method. Both theoretical analysis and actual measurement results show that this method has a simple circuit structure, introduces less circuit noise, and has a low-frequency response improvement effect, which provides an approach for the low-frequency extension of moving coil geophones.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.