Evidence map›Paper›PMID 36991788›Full record

ArticleSensors (Basel, Switzerland)2023

Head-Mounted Display for Clinical Evaluation of Neck Movement Validation with Meta Quest 2.

Manuel Trinidad-Fernández, Benoît Bossavit, Javier Salgado-Fernández, Susana Abbate-Chica, Antonio J Fernández-Leiva, Antonio I Cuesta-Vargas

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
5.1field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 16 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 2 countries.

Manuel Trinidad-FernándezGrupo de Investigación Clinimetría, Departamento de Fisioterapia, Universidad de Málaga, 29071 Málaga, Spain.ORCID 0000-0001-7562-5986
Benoît BossavitITIS Software, Departamento de Lenguajes y Ciencias de la Computación, Universidad de Málaga, Andalucía Tech, 29071 Málaga, Spain.ORCID 0000-0003-1236-3020
Javier Salgado-FernándezDepartamento de Expresión Gráfica, Diseño y Proyectos, Escuela de Ingenierías Industriales, Universidad de Málaga, 29071 Málaga, Spain.ORCID 0000-0003-4540-946X
Susana Abbate-ChicaGrupo de Investigación Clinimetría, Departamento de Fisioterapia, Universidad de Málaga, 29071 Málaga, Spain.
Antonio J Fernández-LeivaITIS Software, Departamento de Lenguajes y Ciencias de la Computación, Universidad de Málaga, Andalucía Tech, 29071 Málaga, Spain.ORCID 0000-0002-5330-5217
Antonio I Cuesta-VargasGrupo de Investigación Clinimetría, Departamento de Fisioterapia, Universidad de Málaga, 29071 Málaga, Spain.ORCID 0000-0002-8880-4315
Universidad de Málaga · ESAndalusian Centre for Nanomedicine and Biotechnology · ESQueensland University of Technology · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Neck disorders have a significant impact on people because of their high incidence. The head-mounted display (HMD) systems, such as Meta Quest 2, grant access to immersive virtual reality (iRV) experiences. This study aims to validate the Meta Quest 2 HMD system as an alternative for screening neck movement in healthy people. The device provides data about the position and orientation of the head and, thus, the neck mobility around the three anatomical axes. The authors develop a VR application that solicits participants to perform six neck movements (rotation, flexion, and lateralization on both sides), which allows the collection of corresponding angles. An InertiaCube3 inertial measurement unit (IMU) is also attached to the HMD to compare the criterion to a standard. The mean absolute error (MAE), the percentage of error (%MAE), and the criterion validity and agreement are calculated. The study shows that the average absolute errors do not exceed 1° (average = 0.48 ± 0.09°). The rotational movement's average %MAE is 1.61 ± 0.82%. The head orientations obtain a correlation between 0.70 and 0.96. The Bland-Altman study reveals good agreement between the HMD and IMU systems. Overall, the study shows that the angles provided by the Meta Quest 2 HMD system are valid to calculate the rotational angles of the neck in each of the three axes. The obtained results demonstrate an acceptable error percentage and a very minimal absolute error when measuring the degrees of neck rotation; therefore, the sensor can be used for screening neck disorders in healthy people.

Indexed as

Smart GlassesVirtual RealityHumansMovementNeckRange of Motion, ArticularRotationMeta Quest 2neckrehabilitationvalidationvirtual reality

Identifiers

PMID36991788
PMCPMC10056752
OpenAlexW4324148932

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.