Evidence map›Paper›PMID 36991785›Full record

ArticleSensors (Basel, Switzerland)2023

A Model Transfer Method among Spectrometers Based on Improved Deep Autoencoder for Concentration Determination of Heavy Metal Ions by UV-Vis Spectra.

Hongqiu Zhu, Yi Shang, Qilong Wan, Fei Cheng, Haonan Hu, Tiebin Wu

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Hongqiu ZhuSchool of Automation, Central South University, Changsha 410083, China.ORCID 0000-0003-0063-0363
Yi ShangSchool of Automation, Central South University, Changsha 410083, China.ORCID 0009-0004-3840-2846
Qilong WanSchool of Automation, Central South University, Changsha 410083, China.
Fei ChengSchool of Automation, Central South University, Changsha 410083, China.
Haonan HuSchool of Automation, Central South University, Changsha 410083, China.
Tiebin WuSchool of Energy and Electromechanical Engineering, Hunan University of Humanities, Science and Technology, Loudi 417000, China.

Funding

Fundamental Research Funds for the Central Universities of Central South University 2021zzts0180National Natural Science Foundation of China 62273360Natural Science Foundation of Hunan Province 2020JJ4382
6 · The paper itself

Abstract

Ultraviolet Visible (UV-Vis) spectroscopy detection technology has been widely used in quantitative analysis for its advantages of rapid and non-destructive determination. However, the difference of optical hardware severely restricts the development of spectral technology. Model transfer is one of the effective methods to establish models on different instruments. Due to the high dimension and nonlinearity of spectral data, the existing methods cannot effectively extract the hidden differences in spectra of different spectrometers. Thus, based on the necessity of spectral calibration model transfer between the traditional large spectrometer and the micro-spectrometer, a novel model transfer method based on improved deep autoencoder is proposed to realize spectral reconstruction between different spectrometers. Firstly, two autoencoders are used to train the spectral data of the master and slave instrument, respectively. Then, the hidden variable constraint is added to enhance the feature representation of the autoencoder, which makes the two hidden variables equal. Combined with a Bayesian optimization algorithm for the objective function, the transfer accuracy coefficient is proposed to characterize the model transfer performance. The experimental results show that after model transfer, the spectrum of the slave spectrometer is basically coincident with the master spectrometer and the wavelength shift is eliminated. Compared with the two commonly used direct standardization (DS) and piecewise direct standardization (PDS) algorithms, the average transfer accuracy coefficient of the proposed method is improved by 45.11% and 22.38%, respectively, when there are nonlinear differences between different spectrometers.

Indexed as

autoencoderheavy metal ionmicro-spectrometermodel transferspectrometry

Identifiers

PMID36991785
PMCPMC10055801

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.