ArticleSensors (Basel, Switzerland)2023
Calibration Model Optimization for Strain Metrology of Equal Strength Beams Using Deflection Measurements.
Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Experimental verification of DAS vibration response characteristics of equal strength beam under sinusoidal excitation.Scientific reports · 2026Article
- Research on a Precision Calibration Model of a Flexible Strain Sensor Based on a Variable Section Cantilever Beam.Sensors (Basel, Switzerland) · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
Strain sensors, especially fiber Bragg grating (FBG) sensors, are of great importance in structural health monitoring, mechanical property analysis, and so on. Their metrological accuracy is typically evaluated by equal strength beams. The traditional strain calibration model using the equal strength beams was built based on an approximation method by small deformation theory. However, its measurement accuracy would be decreased while the beams are under the large deformation condition or under high temperature environments. For this reason, an optimized strain calibration model is developed for equal strength beams based on the deflection method. By combining the structural parameters of a specific equal strength beam and finite element analysis method, a correction coefficient is introduced into the traditional model, and an accurate application-oriented optimization formula is obtained for specific projects. The determination method of optimal deflection measurement position is also presented to further improve the strain calibration accuracy by error analysis of the deflection measurement system. Strain calibration experiments of the equal strength beam were carried out, and the error introduced by the calibration device can be reduced from 10 με to less than 1 με. Experimental results show that the optimized strain calibration model and the optimum deflection measurement position can be employed successfully under large deformation conditions, and the deformation measurement accuracy is improved greatly. This study is helpful to effectively establish metrological traceability for strain sensors and furthermore improve the measurement accuracy of strain sensors in practical engineering scenarious.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.