Evidence map›Paper›PMID 36984960›Full record

ArticleMicromachines2023

Design of a Compact Quad-Channel Microstrip Diplexer for L and S Band Applications.

Sobhan Roshani, Salah I Yahya, Yaqeen Sabah Mezaal, Muhammad Akmal Chaudhary, Aqeel A Al-Hilali, Afshin Mojirleilani, Saeed Roshani

Abstract read
In one paragraph

Article in Micromachines, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Sobhan RoshaniDepartment of Electrical Engineering, Kermanshah Branch, Islamic Azad University, Kermanshah 6718997551, Iran.ORCID 0000-0001-5088-499X
Salah I YahyaDepartment of Communication and Computer Engineering, Cihan University-Erbil, Erbil 44001, Iraq.ORCID 0000-0002-2724-5118
Yaqeen Sabah MezaalMedical Instrumentation Engineering Department, Al-Esraa University College, Baghdad 10011, Iraq.
Muhammad Akmal ChaudharyDepartment of Electrical and Computer Engineering, College of Engineering and Information Technology, Ajman University, Ajman 346, United Arab Emirates.ORCID 0000-0001-6063-3377
Aqeel A Al-HilaliCollege of Medical Techniques, Al-Farahidi University, Baghdad 10011, Iraq.
Afshin MojirleilaniDepartment of Electrical Engineering, Kermanshah Branch, Islamic Azad University, Kermanshah 6718997551, Iran.
Saeed RoshaniDepartment of Electrical Engineering, Kermanshah Branch, Islamic Azad University, Kermanshah 6718997551, Iran.ORCID 0000-0002-4024-2755

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In this paper, two novel dual-band bandpass filters (BPFs) and a compact quad-channel diplexer working at 1.7/3.3 GHz and 1.9/3.6 GHz are proposed. In the proposed diplexer design, triangular loop resonators and rectangular loop resonators are used together to reduce the circuit size and improve diplexer performances. Insertion loss (IL) and return loss (RL) of the proposed diplexer are better than 0.8 dB and 21 dB, respectively, at these four operating frequencies. Output ports isolation parameter is better than 30 dB. With the achieved specifications, the proposed diplexer can be used in L and S band applications.

Indexed as

bandpass filtercoupled linesdiplexerinsertion lossmicrostripquad-channelresonatorreturn loss

Identifiers

PMID36984960
PMCPMC10058204

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.