ArticleMicromachines2023
Measurement of Complex Permittivity for Rapid Detection of Liquid Concentration Using a Reusable Octagon-Shaped Resonator Sensor.
Article in Micromachines, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- An Enhanced Q-Factor Cantilever Resonator in Viscous Liquids Using Strategic Perforation.Micromachines · 2026Article
- Microwave Sensor for Dielectric Constant of Lossy Organic Liquids Based on Negative-Resistance Oscillation.Sensors (Basel, Switzerland) · 2025Article
- Wave Impedance Determination for PCB SIWs Considering Metal Roughness Loss Effects.Micromachines · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
Substrate-integrated waveguides (SIWs) are widely used in microwave systems owing to their low cost and ease of integration. In this study, an SIW-based resonator that reacts to the complex permittivity variation of solutions with dimensions of 79.2 mm × 59.8 mm is introduced. This octagon-shaped sensor can be installed on a preliminary monitoring system to test water quality by observing the parameter variations caused by external factors. The resonant structure was used to test different concentrations of ethanol-water and acetone-water mixtures for verification. The resonant frequency and quality factor (Q-factor) were found to vary with the relative complex permittivity of the liquid in the S-band, and the electric field distribution varied when liquid droplets were placed in the center of the substrate. The designed sensor operates at 2.45 GHz in the air, and the observed minimum resonant frequency shift with liquid was 15 MHz. The measurement error was approximately 3.1%, and the results reveal a relationship between the resonant frequency and temperature as well. Considering the observed sources of error, the measured relative permittivity is consistent with the actual values. The proposed sensor is economically convenient and suitable for various test environments.
Indexed as
Identifiers
What OpenQuestion holds