Evidence map›Paper›PMID 36984948›Full record

ArticleMicromachines2023

Measurement of Complex Permittivity for Rapid Detection of Liquid Concentration Using a Reusable Octagon-Shaped Resonator Sensor.

Chun-He Quan, Xiao-Yu Zhang, Jong-Chul Lee

Abstract read
In one paragraph

Article in Micromachines, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Chun-He QuanJCET Stats ChipPAC Korea, Jayumuyeok-ro, Jung-gu, Incheon 22397, Republic of Korea.
Xiao-Yu ZhangDepartment of Electronic Convergence Engineering, Kwangwoon University, 20 Kwangwoon-ro, Nowon-gu, Seoul 01897, Republic of Korea.ORCID 0000-0002-2745-1042
Jong-Chul LeeDepartment of Electronic Convergence Engineering, Kwangwoon University, 20 Kwangwoon-ro, Nowon-gu, Seoul 01897, Republic of Korea.ORCID 0000-0002-7854-6180

Funding

Kwangwoon University 2021-0826
6 · The paper itself

Abstract

Substrate-integrated waveguides (SIWs) are widely used in microwave systems owing to their low cost and ease of integration. In this study, an SIW-based resonator that reacts to the complex permittivity variation of solutions with dimensions of 79.2 mm × 59.8 mm is introduced. This octagon-shaped sensor can be installed on a preliminary monitoring system to test water quality by observing the parameter variations caused by external factors. The resonant structure was used to test different concentrations of ethanol-water and acetone-water mixtures for verification. The resonant frequency and quality factor (Q-factor) were found to vary with the relative complex permittivity of the liquid in the S-band, and the electric field distribution varied when liquid droplets were placed in the center of the substrate. The designed sensor operates at 2.45 GHz in the air, and the observed minimum resonant frequency shift with liquid was 15 MHz. The measurement error was approximately 3.1%, and the results reveal a relationship between the resonant frequency and temperature as well. Considering the observed sources of error, the measured relative permittivity is consistent with the actual values. The proposed sensor is economically convenient and suitable for various test environments.

Indexed as

liquid concentrationoctagon-shaped sensorradio frequencyrelative complex permittivitysubstrate integrated waveguide cavity

Identifiers

PMID36984948
PMCPMC10051991

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.