Barbed Dental Ti6Al4V Alloy Screw: Design and Bench Testing.

Keila Lovera-Prado, Vicente Vanaclocha, Carlos M Atienza, Amparo Vanaclocha, Pablo Jordá-Gómez, Nieves Saiz-Sapena, Leyre Vanaclocha

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Keila Lovera-PradoCIRU-IMPLANT, S.L., Avenida Cornellà, 2-BJ, Esplugues de Llobregat, 08950 Barcelona, Spain.
Vicente VanaclochaDepartment of Surgery, School of Medicine, University of Valencia, 46010 Valencia, Spain.
Carlos M AtienzaBiomechanical Engineer, Biomechanics Institute of Valencia, Polytechnic University of Valencia, 46022 Valencia, Spain.
Amparo VanaclochaBiomechanical Engineer, Biomechanics Institute of Valencia, Polytechnic University of Valencia, 46022 Valencia, Spain.
Pablo Jordá-GómezHospital General Universitario de Castellón, 12004 Castellón de la Plana, Spain.ORCID 0000-0003-0160-4431
Nieves Saiz-SapenaHospital General Universitario de Valencia, 46014 Valencia, Spain.ORCID 0000-0001-7816-3617
Leyre VanaclochaMedius Klinik, Ostfildern-Ruit Klinik für Urologie, Hedelfinger Strasse 166, 73760 Ostfildern, Germany.

Funding

CIRU-IMPLANT It is a private dental clinic
6 · The paper itself

Abstract

background contextDental implants are designed to replace a missing tooth. Implant stability is vital to achieving osseointegration and successful implantation. Although there are many implants available on the market, there is room for improvement. PURPOSE: We describe a new dental implant with improved primary stability features. STUDY

designLab bench test studies.

methodsWe evaluated the new implant using static and flexion-compression fatigue tests with compression loads, 35 Ncm tightening torque, displacement control, 0.01 mm/s actuator movement speed, and 9-10 Hz load application frequency, obtaining a cyclic load diagram. We applied variable cyclic loadings of predetermined amplitude and recorded the number of cycles until failure. The test ended with implant failure (breakage or permanent deformation) or reaching five million cycles for each load.

resultsMean stiffness was 1151.13 ± 133.62 SD N/mm, mean elastic limit force 463.94 ± 75.03 SD N, and displacement 0.52 ± 0.04 SD mm, at failure force 663.21 ± 54.23 SD N and displacement 1.56 ± 0.18 SD mm, fatigue load limit 132.6 ± 10.4 N, and maximum bending moment 729.3 ± 69.43 mm/N.

conclusionsThe implant fatigue limit is satisfactory for incisor and canine teeth and between the values for premolars and molars for healthy patients. The system exceeds five million cycles when subjected to a 132.60 N load, ensuring long-lasting life against loads below the fatigue limit.

Indexed as

3D printingbone–implant interactionsosseointegrationporous implantstitanium implants

Identifiers

PMID36984107
PMCPMC10054258

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.