Comparative Study of Dental Custom CAD-CAM Implant Abutments and Dental Implant Stock Abutments.

Daniel Adrian Târtea, Mihaela Ionescu, Horia Octavian Manolea, Veronica Mercuț, Eugenia Obădan, Marina Olimpia Amărăscu, Petre Costin Mărășescu, Luminița Dăguci, Sanda Mihaela Popescu

Open access · goldAbstract read
In one paragraph

Article in Journal of clinical medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
5.2field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 25 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Clinical outcome of narrow diameter dental implants: a 3-year retrospective study.Maxillofacial plastic and reconstructive surgery · 2023
    Article
  11. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Daniel Adrian TârteaDepartment of Oral Rehabilitation, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania.
Mihaela IonescuDepartment of Medical Informatics and Biostatistics, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania.
Horia Octavian ManoleaDepartment of Dental Materials, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania.
Veronica MercuțDepartment of Dental Prosthetics, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania.
Eugenia ObădanDepartment of Dental Materials, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania.
Marina Olimpia AmărăscuDepartment of Dental Morphology, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania.
Petre Costin MărășescuDepartment of Dental Technology, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania.
Luminița DăguciDepartment of Dental Prosthetics, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania.
Sanda Mihaela PopescuDepartment of Oral Rehabilitation, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania.ORCID 0000-0003-3011-6322
University of Medicine and Pharmacy of Craiova · RO

Funding

CSRD VA 1
6 · The paper itself

Abstract

The implementation of CAD-CAM systems in dentistry has significantly influenced the evolution of dental implantology and implant-supported prosthetics within the past three decades. Implant-supported prostheses are comfortable and aesthetic. The prosthetic abutment has also faced a rapid design evolution, from the individualization of standard stock abutments offered by various manufacturers to a modern customization process using CAD-CAM technology. This paper presents a comparative study between 20 dental custom CAD-CAM implant abutments and 20 dental implant stock abutments, based on a set of measurements performed on the digital casts obtained from 24 cases of prosthetic rehabilitation on implants. The statistical analysis (Mann-Whitney U test) revealed significant differences between these two types of abutments: the incisal margin line diameter dimensions for custom abutments were significantly improved compared to standard abutments at the cervical level (U = 343.00, z = 3.868,

Indexed as

CAD/CAMdental prosthesesdental technologyevaluation methods

Identifiers

PMID36983129
PMCPMC10054898
OpenAlexW4323664645

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.