Evidence map›Paper›PMID 36980453›Full record

ArticleDiagnostics (Basel, Switzerland)2023

Real-Time Elastography versus Shear Wave Elastography on Evaluating the Timely Radiofrequency Ablation Effect of Rabbit Liver: A Preliminary Experimental Study.

Li Shi, Xiaoju Li, Wei Liao, Wenxin Wu, Ming Xu

Open access · goldFull text read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.4field-weighted citation impact, top 44% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Li ShiDepartment of Medical Ultrasonics, Hainan General Hospital, Haikou 570311, China.
Xiaoju LiDepartment of Medical Ultrasonics, The First Affiliated Hospital, Institute of Diagnostic and Interventional Ultrasound, Sun Yat-sen University, Guangzhou 510080, China.
Wei LiaoDepartment of Medical Ultrasonics, Hainan General Hospital, Haikou 570311, China.
Wenxin WuDepartment of Medical Ultrasonics, The First Affiliated Hospital, Institute of Diagnostic and Interventional Ultrasound, Sun Yat-sen University, Guangzhou 510080, China.
Ming XuDepartment of Medical Ultrasonics, The First Affiliated Hospital, Institute of Diagnostic and Interventional Ultrasound, Sun Yat-sen University, Guangzhou 510080, China.
Hainan General Hospital · CNSun Yat-sen University · CNThe First Affiliated Hospital, Sun Yat-sen University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeto evaluate and monitor the timely thermal ablation changes of rabbit liver by using two elastographic methods-real-time elastography (RTE) and shear wave elastography (SWE)-as compared to contrast-enhanced ultrasound (CEUS) and physical specimens. MATERIALS AND

methods20 ablation zones were created in the livers of 20 rabbits using radiofrequency ablation (RFA). After the ablation, RTE and SWE were used to measure the elastic properties of the twenty ablation zones. The consistency of efficacy evaluation for RTE and SWE measurements was analyzed using the Bland-Altman test. The areas of the thermal ablation zones were also measured and compared according to the images provided by RTE, SWE, CEUS, and gross physical specimen measurement.

resultsRTE and SWE could clearly display the shape of RFA ablation zones within one hour after the ablation. The average elasticity ratio for the ablation zone measured by RTE was 3.41 ± 0.67 (2.23-4.76); the average elasticity value measured by SWE was 50.7 ± 11.3 kPa (33.2-70.4 kPa). The mean areas of the ablation zones measured with RTE, SWE, gross specimen, and CEUS were 1.089 ± 0.199 cm

conclusionRTE and SWE are both able to accurately confirm the range of ablation zones shortly after the ablation for rabbit livers.

Indexed as

contrast-enhanced ultrasoundliverradiofrequency ablationreal-time elastographyshear wave elastography

Identifiers

PMID36980453
PMCPMC10046930
OpenAlexW4327731527

What OpenQuestion holds

Textfull text, public
LicenceCC BY
measurements read11
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.