Evidence map›Paper›PMID 36979543›Full record

ArticleBiosensors2023

Electrochemical Sensing of Urinary Chloride Ion Concentration for Near Real-Time Monitoring.

Anna M Nelson, Sanaz Habibi, John O L DeLancey, James A Ashton-Miller, Mark A Burns

Open access · goldFull text read
In one paragraph

Article in Biosensors, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.8field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 9 citations in OpenAlex.

  1. Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Anna M NelsonDepartment of Chemical Engineering, University of Michigan, Ann Arbor, MI 48109, USA.ORCID 0000-0002-9301-6161
Sanaz HabibiDepartment of Chemical Engineering, University of Michigan, Ann Arbor, MI 48109, USA.ORCID 0000-0002-3736-0574
John O L DeLanceyDepartment of Obstetrics & Gynecology, University of Michigan, Ann Arbor, MI 48109, USA.ORCID 0000-0002-1012-7713
James A Ashton-MillerDepartment of Mechanical Engineering, University of Michigan, Ann Arbor, MI 48109, USA.ORCID 0000-0003-1528-2787
Mark A BurnsDepartment of Chemical Engineering, University of Michigan, Ann Arbor, MI 48109, USA.
University of Michigan · US

Funding

Research Education CoreP30AG024824 · NIA · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI Neil Alexander · 2004 to 2026
$29.2M
Development of 21st Century Concepts and Tools for Quantifying Urethral Failure Mechanisms that Cause Urinary IncontinenceRC2DK122379 · NIDDK · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI ASHTON-MILLER, JAMES ANTHONY, DELANCEY, JOHN O.L. · 2019 to 2024
$5.7M
NIA NIH HHS P30 AG024824NIDDK NIH HHS RC2 DK122379United States Public Health Service P30 AG 024824 & RC2 DK122379
6 · The paper itself

Abstract

Urinary chloride concentration is a valuable health metric that can aid in the early detection of serious conditions, such as acid base disorders, acute heart failure, and incidences of acute renal failure in the intensive care unit. Physiologically, urinary chloride levels frequently change and are difficult to measure, involving time-consuming and inconvenient lab testing. Thus, near real-time simple sensors are needed to quickly provide actionable data to inform diagnostic and treatment decisions that affect health outcomes. Here, we introduce a chronopotentiometric sensor that utilizes commercially available screen-printed electrodes to accurately quantify clinically relevant chloride concentrations (5-250 mM) in seconds, with no added reagents or electrode surface modification. Initially, the sensor's performance was optimized through the proper selection of current density at a specific chloride concentration, using electrical response data in conjunction with scanning electron microscopy. We developed a unique swept current density algorithm to resolve the entire clinically relevant chloride concentration range, and the chloride sensors can be reliably reused for chloride concentrations less than 50 mM. Lastly, we explored the impact of pH, temperature, conductivity, and additional ions (i.e., artificial urine) on the sensor signal, in order to determine sensor feasibility in complex biological samples. This study provides a path for further development of a portable, near real-time sensor for the quantification of urinary chloride.

Indexed as

ChloridesElectrochemical TechniquesElectrodesMicroscopy, Electron, ScanningChlorideschronopotentiometryelectrochemical sensorurinary chloride detection

Identifiers

PMID36979543
PMCPMC10046868
OpenAlexW4322587968

What OpenQuestion holds

Textfull text, public
LicenceCC BY
measurements read57
table measurements read3
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.