ArticleBioengineering (Basel, Switzerland)2023
SenGlove-A Modular Wearable Device to Measure Kinematic Parameters of The Human Hand.
Article in Bioengineering (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 4 citations in OpenAlex.
- Clinical efficacy of the mulligan maneuver for cervicogenic headache: a randomized controlled trial.Scientific reports · 2023Trial
- A Biomimetic Four-Chamber Soft Actuator for Human-like Dexterous Manipulation with Spatial Bending and Twisting Capabilities.Biomimetics (Basel, Switzerland) · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
For technical or medical applications, the knowledge of the exact kinematics of the human hand is key to utilizing its capability of handling and manipulating objects and communicating with other humans or machines. The optimal relationship between the number of measurement parameters, measurement accuracy, as well as complexity, usability and cost of the measuring systems is hard to find. Biomechanic assumptions, the concepts of a biomechatronic system and the mechatronic design process, as well as commercially available components, are used to develop a sensorized glove. The proposed wearable introduced in this paper can measure 14 of 15 angular values of a simplified hand model. Additionally, five contact pressure values at the fingertips and inertial data of the whole hand with six degrees of freedom are gathered. Due to the modular design and a hand size examination based on anthropometric parameters, the concept of the wearable is applicable to a large variety of hand sizes and adaptable to different use cases. Validations show a combined root-mean-square error of 0.99° to 2.38° for the measurement of all joint angles on one finger, surpassing the human perception threshold and the current state-of-the-art in science and technology for comparable systems.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.