Evidence map›Paper›PMID 36975343›Full record

ArticleBiomimetics (Basel, Switzerland)2023

An Investigation of the Fracture Loads Involved in the Framework of Removable Partial Dentures Using Two Types of All-Ceramic Restorations.

Fahad Hussain Alhamoudi, Lujain Ibrahim N Aldosari, Abdulkhaliq Ali F Alshadidi, Saeed Awod Bin Hassan, Maram Ali M Alwadi, Sunil Kumar Vaddamanu, Marco Cicciù, Giuseppe Minervini

Open access · goldFull text read
In one paragraph

Article in Biomimetics (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.3field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 2 countries.

Fahad Hussain AlhamoudiDental Technology Department, College of Applied Medical Science, King Khalid University, Abha 61421, Saudi Arabia.ORCID 0000-0002-8391-1787
Lujain Ibrahim N AldosariDepartment of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha 61421, Saudi Arabia.ORCID 0000-0002-8419-410X
Abdulkhaliq Ali F AlshadidiDental Technology Department, College of Applied Medical Science, King Khalid University, Abha 61421, Saudi Arabia.
Saeed Awod Bin HassanDepartment of Restorative Dental Sciences, College of Dentistry, King Khalid University, Abha 61421, Saudi Arabia.ORCID 0000-0002-6658-5123
Maram Ali M AlwadiDental Health Department, College of Applied Medical Science, King Saud University, Riyadh 11451, Saudi Arabia.ORCID 0000-0001-7796-4850
Sunil Kumar VaddamanuDental Technology Department, College of Applied Medical Science, King Khalid University, Abha 61421, Saudi Arabia.ORCID 0000-0002-1583-3246
Marco CicciùDepartment of General Surgery and Medical-Surgical Specialties, School of Dentistry, University of Catania, 95124 Catania, Italy.ORCID 0000-0001-7058-4126
Giuseppe MinerviniMultidisciplinary Department of Medical-Surgical and Odontostomatological Specialties, University of Campania "Luigi Vanvitelli", 80121 Naples, Italy.ORCID 0000-0002-8309-1272
King Khalid University · SAKing Saud University · SAUniversity of Campania "Luigi Vanvitelli" · ITUniversity of Catania · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Retention and support are needed for removable partial denture stability. The stability can be achieved by clasps, occlusal and cingulum rests on healthy abutment teeth. However, implants or crowns can be used to support the removable partial denture instated on unhealthy abutment teeth. This study was conducted to investigate the fracture strength of two types of all-ceramic restorations used as abutments for the removable partial denture framework. The crowns were manufactured with two types of ceramic materials: zirconia and IPS e.max Press ceramics. The metal alloy (cobalt-chrome) was cast to form the removable partial denture framework. A universal testing machine was used to evaluate the fracture strength of both ceramic crown materials. The results presented no fractures in all-ceramic crowns, but deformation of the partial denture frameworks occurred. With the limitation of this study, it can be concluded that zirconia and IPS e.max Press ceramic can be used as abutments to provide adequate support to the removable partial denture.

Indexed as

ceramic crownsfracture strengthremovable partial denture

Identifiers

PMID36975343
PMCPMC10046878
OpenAlexW4323845451

What OpenQuestion holds

Textfull text, public
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.