ArticlePloS one2023
The use of remote Femto Second technology in the preparation of black silicon material and optical devices.
Article in PloS one, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The research aims to study the application of remote Femto Second (FS) technology in black silicon material preparation and optical devices. Based on the principle and characteristic research of FS technology, the interaction between FS and silicon is adopted to propose a scheme for preparing black silicon material through experiments. Moreover, the experimental parameters are optimized. Then, the scheme of using the FS for etching polymer optical power splitter as a new technical means is proposed. In addition, while ensuring processing accuracy, the appropriate process parameters of laser etching photoresist are obtained. The results show that the performance of black silicon prepared with SF6 as the background gas is greatly improved in the 400-2200nm range. However, the performance of black silicon samples with the two-layer structure etched at different laser energy densities has little difference. Black silicon with a Se+Si two-layer film structure has the best optical absorption performance in the infrared range of 1100nm-2200nm. Besides, the optical absorption rate is the highest when the laser scanning rate is 0.5mm/s. In the band of >1100nm, when the maximum laser energy density is 6.5kJ/m2, the overall absorption of the etched sample is the worst. The absorption rate is the best when the laser energy density is 3.9kJ/m2. It suggests that the proper parameter selection greatly impacts the quality of the final laser-etched sample.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.