Evidence map›Paper›PMID 36970335›Full record

ReviewFrontiers in cardiovascular medicine2023

Polymeric prosthetic heart valves: A review of current technologies and future directions.

Sameer K Singh, Mateusz Kachel, Estibaliz Castillero, Yingfei Xue, David Kalfa, Giovanni Ferrari, Isaac George

Full text readReview
In one paragraph

Review in Frontiers in cardiovascular medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 39 papers.

0numbers the graph read from it
0cells of the map it votes in
39citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

39 citing papers in PubMed.

  1. Review
  2. Innovation and Challenges in Materials for Transcatheter Aortic Valves.Journal of cardiovascular translational research · 2026
    Review
  3. Article
  4. Article
  5. Article
  6. Review
  7. Review
  8. Review
  9. Review
  10. [Numerical simulation study on the influence of free edge configuration on the performance of polymeric heart valves].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2026
    Article
  11. Article
  12. Article
  13. Review
  14. Review
  15. Woven solutions for tissue engineering: Next-generation heart valves from fiber to function.American heart journal plus : cardiology research and practice · 2025
    Article
  16. Review
  17. Review
  18. Review
  19. Biomimetic Polyurethanes in Tissue Engineering.Biomimetics (Basel, Switzerland) · 2025
    Review
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Sameer K SinghDivision of Cardiothoracic Surgery, New York Presbyterian Hospital, College of Physicians and Surgeons of Columbia University, New York, NY, United States.
Mateusz KachelCardiovascular Research Foundation, New York, NY, United States.
Estibaliz CastilleroDivision of Cardiothoracic Surgery, New York Presbyterian Hospital, College of Physicians and Surgeons of Columbia University, New York, NY, United States.
Yingfei XueDivision of Cardiothoracic Surgery, New York Presbyterian Hospital, College of Physicians and Surgeons of Columbia University, New York, NY, United States.
David KalfaDivision of Cardiothoracic Surgery, New York Presbyterian Hospital, College of Physicians and Surgeons of Columbia University, New York, NY, United States.
Giovanni FerrariDivision of Cardiothoracic Surgery, New York Presbyterian Hospital, College of Physicians and Surgeons of Columbia University, New York, NY, United States.
Isaac GeorgeDivision of Cardiothoracic Surgery, New York Presbyterian Hospital, College of Physicians and Surgeons of Columbia University, New York, NY, United States.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Valvular heart disease is an important source of cardiovascular morbidity and mortality. Current prosthetic valve replacement options, such as bioprosthetic and mechanical heart valves are limited by structural valve degeneration requiring reoperation or the need for lifelong anticoagulation. Several new polymer technologies have been developed in recent years in the hope of creating an ideal polymeric heart valve substitute that overcomes these limitations. These compounds and valve devices are in various stages of research and development and have unique strengths and limitations inherent to their properties. This review summarizes the current literature available for the latest polymer heart valve technologies and compares important characteristics necessary for a successful valve replacement therapy, including hydrodynamic performance, thrombogenicity, hemocompatibility, long-term durability, calcification, and transcatheter application. The latter portion of this review summarizes the currently available clinical outcomes data regarding polymeric heart valves and discusses future directions of research.

Indexed as

aortic valveheart valvepolymerpolymer valvetranscatheter and surgical aortic valve replacement

Identifiers

PMID36970335
PMCPMC10034107

What OpenQuestion holds

Textfull text, public
LicenceCC BY
measurements read34
Read underepoch 390

Registered trials

None linked